X.25 Configuration Files and Examples
Example Files
Appendix B 229
# Level 3 Parameters
# Mandatory Parameters - virtual circuit parameters
# logical channel id, start num [1-4095], type, how many
# At least one lci type (PVC, incoming, two-way or outgoing SVC)
# needs to be configured.
#lci 1 pvc 5
#lci 255 insvc 5
#lci 2048 svc 6
#lci 3072 outsvc 6
# 5 permanent VCs starting at LCI 1
# 5 one-way incoming SVCs starting at LCI
255
# 6 two-way switched SVCs starting at LCI
2048
# 6 one-way outgoing SVCs starting at LCI
3072
networktype DTE_84
fast_select disabled
reverse_charge
disabled
# CCITT 1984, DTE (see
/etc/x25/x25_networks)
# disallow incoming calls with call user
data
# disallow incoming calls requesting
reverse changes
def_inpacketsize 128
def_outpacketsize 128
def_inwindow 2
def_outwindow 2
# def_inthruputclass
19200
# def_outthruputclass
19200
# default packetsize
# default packetsize
# default window size
# default window size
# default thruput class
# default thruput class
flowcontrol off
neg_inpacketsize 128
neg_outpacketsize 128
neg_inwindow 2
neg_outwindow 2
# flow control negotiation not allowed
# offered pkt size if using flow control
negotiation
# offered pkt size if using flow control
negotiation
# offered wndw size if using flow control
negotiation
# offered wndw size if using flow control
negotiation
thruputclass off
Table B-6 (Continued)