PAD Ser vices
Local PAD Emulation (padem)
Chapter 6158
name Optional. This is the name of the programmatic
interface used for call setup. If this entry does not exist,
the default name associated with /dev/x25_0 is used.
This name must match the programmatic access name
(also called name) in the X.25 configuration file.
logging Optional. Specifies the logging level that applies to all
calls made during this session. The log file is
$HOME/plog.aXXXXX, where the last five characters are
from the process ID of padem. If this parameter is not
specified, the logging level is set to the default level of 0
(no logging). Logging levels are: 1 = error logging, 2 =
error and warning logging, 3 = error, warning,
information, and status logging.
reverse_charge Optional. Specifies the reverse charge option for call
setup. Possible settings are: disabled (or disable)
and enabled (or enable). The default value is
disabled. When reverse charge is enabled, padem
sends a reverse charge request with all call request
packets.
profile Optional. Describes the X.3 configuration for the login
session. The X.3 default values are defined in the code
(programmatically) and cannot be altered by users.
These default parameters comply with the 1984 profile
0 specification for a PAD device. If profile X is in
x29hosts and profile Y=X is in x3config, padem uses
profile X. If there is no profile in x29hosts, and
x3config contains profile 0, padem uses profile 0. In all
other cases padem uses the hard-coded default values.
padem only operates in line mode for X.3 configuration.
host_table{} Optional. Defines symbolic host names for remote
X.121 addresses. The first entry defines the symbolic
name and the second entry is the remote X.121
address. If an X.121 address is given, it must also exist
in the remote_x121 field in the pad_em section of the
x29hosts file.
NOTE You do NOT need to have pad_em {} entries in the
x29hosts file. You can specify all of the above
parameters at the command line when you run padem.