12. If necessary, manually power on the servers.
Resolving an EMU upgrade issue
When upgrading the EMU firmware, if the EMU and the server blade initiating the upgrade are
not on the same subnet, the upgrade fails. The following message (an example) displays on the
Firmware tab of the System Monitoring and Maintenance tool:
Flash failed for Enclosure Management Unit (EMU) using cpXXXXXX.exe.
Check log files (C:\ProgramData\Hewlett-Packard\CMP\logs\firmware.log
and C:\CPQSYSTEM\log\cpqsetup.log) for further information.
The C:\CPQSYSTEM\log\EmuFlash.log displays the following information (an example only):
Enclosure Manager information:Product Name : HP CSP EMUPart Number :
620022-001Serial Number : PBCYU0G9V0C01XUUID :
99PBCYU0G9V0C01XManufacturer
: HPFirmware Ver. : EM: 1.10 Jul 12 2011; HM: 1.3EMU Type : 1Hw Version
: Rev. BAux Info : SVN: 3221 branches/QUIRE-CSP-1-10
1.10 Jul 12 2011
Starting Flash Routine
Launching Http Server
Host IP Address:
Host IP not found
If this issue occurs, configure the EMU and server blade networking to be on the same subnet and
retry the firmware upgrade.
Performing a coordinated reboot
A coordinated reboot requires that both server blades in the StoreEasy 5000 be shut down as part
of the firmware update process. Therefore, HP recommends that you perform this during a
maintenance window. While the system services will become available during this process,
maintenance is not complete until all the steps below have been completed. Using iLO, follow these
steps to complete the procedure:
1. Run the FMT on the server in slot 2 (lower slot). Once it has finished, power down the server
in slot 2.
2. Run the FMT on the server in slot 1 (upper slot). Once it has finished, power down the server
in slot 1.
NOTE: Firmware updates for the P1210m controller and any storage hard drives may take
some time to complete.
3. Wait approximately 30 seconds.
4. Press the power button on the blade in slot 1.
IMPORTANT: If the system is powered by less than 200 volts (for example, 110), you must
wait for blade 1 to complete its boot process before turning on the second blade.
5. Power on the blade in slot 2.
6. Run the FMT again to verify that the firmware updates have completed on the server in slot 1.
7. Run the FMT again to verify that the firmware updates have completed on the server in slot 2.
Upgrading hardware components
To replace a hardware component with an upgrade, follow the component removal and replacement
instructions in “Removing and replacing hardware components” (page 77). For example, to replace
Performing a coordinated reboot 75