HP 10TB Betriebsanweisung Seite 48

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 181
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 47
Table 13 Known issues (continued)
ResolutionIssue
for more information (where xxxx
is internal or external and yyyy is the
path and name of the log file).
Identify and reseat the SAS I/O module that is causing the issue. An I/O
module may need to be replaced if there is less information available for
one I/O module than the other.
If the System Management Homepage
lists a fan module as unknown or
dormant, it might not be a fan issue. It
may mean that a SAS I/O module needs
to be reseated.
An alert is generated for cache and supercapacitor (cache backup) issues,
but you can also run the following command from a command prompt or
PowerShell to determine the issue:
If the cache on the 1210m controller in
either server blade of the HP StoreEasy
5000 Storage becomes disabled, it will
ccu show controller all details
If the output is similar to the following, replace the cache module or
supercapacitor:
greatly affect performance. As a
protective measure to ensure the safety
of data, if either 1210m controller
experiences an issue requiring the cache
controller 0: 500143800442D690
Manufacturer: HP
to be disabled, the cache is disabled on
both controllers. This results in the
Model: 1210m
reduction of performance for both
Part Number: 607190-001
controllers until the degraded part is
repaired or replaced.
SKU: None
Serial Number: PBGJR0XTAZ40FK
Firmware Version: 0156
Firmware Build: 2011061702
Peer Controller: 500143800442E600
Operational Status: Degraded, Cache disabled: redundant
controller battery issue
Health Status: Degraded/Warning
Cache Size: 1073741824
Read Cache Default: Enabled
Write Cache Default: Enabled
Battery 0 Status: fully charged
Battery 0 Estimated Charge Remaining: 100%
controller 1: 500143800442E600
Manufacturer: HP
Model: 1210m
Part Number: 607190-001
SKU: None
Serial Number: PBGJR0XTAZ407Z
Firmware Version: 0156
Firmware Build: 2011061702
Peer Controller: 500143800442D690
Operational Status: Degraded, Cache flash backup
hardware failure, Cache disabled: low battery charge
Health Status: Degraded/Warning
Cache Size: 1073741824
Read Cache Default: Enabled
Write Cache Default: Enabled
Battery 0 Status: charging
Battery 0 Estimated Charge Remaining: 0%
When configuring iLO settings, changing
iLO settings on the second node may
Log on to the second node using the local administrator account and
configure the iLO settings using the iLO Configuration Utility in the HP
System Tools program group.
result in an error that the user has
insufficient permissions. This can happen
Connect to iLO and change the settings using the iLO user interface.
even if the user is a domain administrator
and belongs to the administrator group
NOTE: Changing the iLO network settings may cause your iLO sessions to
disconnect.
on each node. The User Access Control
system prevents the application from
running on the second node. No prompt
is displayed to the user to allow
execution on the second node.
Delete existing LUNs by selecting Windows Server Manager File and
Storage Services after installing the System Recovery image. In Windows
You have installed the System Recovery
image on a storage system that has an
48 Monitoring and troubleshooting the storage system
Seitenansicht 47
1 2 ... 43 44 45 46 47 48 49 50 51 52 53 ... 180 181

Kommentare zu diesen Handbüchern

Keine Kommentare