Table 18 Firmware Management Tool (FMT) errors (continued)
Troubleshooting tipsRoot causeMessage formatError code
Components\CMP folder along with
FW bundle if needed (Follow the
same steps mentioned in first four
error scenarios).
Check the logs for more information
and act accordingly.
SC failed to discover the active
version.
Discovery failed for %s using %s.
Check log file %s for more
information.
0X1A0E
Make sure that EM is up and
reachable from server and then retry
the operation.
Failed to communicate to EM because
of connectivity issue.
Failure communicating with Enclosure
Manager (EM) - check that EM is up
and can be reached from server: see
the log file (%s) for more information.
0x1A11
Make sure that EM keys are
generated properly.
1. Open Enclosure Manager Settings
utility and enter correct EM password
.
EM authentication failure.Discovery failed for %s using %s:
Authentication failed while connecting
to Enclosure Manager (EM).
0x1A12
Flash not attempted for %s using %s:
Authentication failed while connecting
to Enclosure Manager (EM).
0x1034
2. Retry the operation.
Check the logs for more info and act
accordingly.
Flash failed.Flash failed for %s using %s. Check
log files (%s and %s) for further
information.
0x1011
Flash failed for %s using %s. Check
log file (%s) for further information.
0x1012
Smart Component flash failed for %s
using %s. Check log files: %s, %s and
%s.
0x1015
Wait for sometime, check whether
newer version is reflected by
Devices which require (like SEPs) reset
post flash hung during the reset
process.
Flash failed for %s using %s: the
device hung on reset.
0x1013
discovering the affected components.
If not retry the operation.
System too busy to respond or
component not responding to flash
call in specified timeout period
Smart Component flash failed for %s
using %s: wait for flash status timed
out. Check log files: %s, %s and %s.
0x1014
Make sure the connectivity between
EM and server is proper and then
retry the flash operation.
EM is not reachable from server.Enclosure Manager Firmware Update
Failed (EMU can't access server's IP
Address). Check log files: %s and %s.
0x106C
Need to diagnose Storage Enclosure
and P1210m controller to get details
Could not retrieve information about
HDDs prior to flashing the storage.
Failed to retrieve HDD information
before flashing %s using %s , Please
0x1031
of all attached HDD available in
enclosure is in OK state.
check the log file (%s) for further
details.
Ensure to have supported
configuration hardware is present on
appliance.
HDD present on server or enclosure
are not supported for appliance.
Flash not attempted for %s using %s:
Drive model(s) not supported. Check
log file (%s) for further information.
0x1036
Ensure to have Cache board on
servers.
Flash not attempted for internal server
HDDs as P410i Smart Array
Flash not attempted for %s using %s:
P410i Smart Array Controller Cache
0x1037
Controller Cache Board is not present.Board is not present. Cache board is
Cache board is needed to flash the
internal server HDD.
needed to flash the internal server
HDD.
Retry the operation.Operation timed out for device
<device name>.
Operation failed for device: %s :
operation timed out; check log file %s
for more information.
0x1A13
Reinstall dan library as local admin.
Dan lib can be found at c:\hpnas\
components\ccu.
Dan library not found or no proper
permissions.
Internal error - Either %s is missing or
not readable. Check log file (%s) for
more information.
0x1A23