• Enclosure HDD
• ILO3
• BIOS
• Power Management Ctrl
• Embedded NIC – NC553i
• NC382m
• Embedded Smart Array Ctrl – P410i
• P1210m controller
• Server HDD
3. Reboot server blade 1 if required.
If the system is in a cluster, perform the following steps before rebooting. This ensures the file
system is not affected.
a. Select Windows Server Manager→Tools→Failover Cluster Manager.
b. Select the cluster. Expand the navigation tree for the cluster if it is not already expanded.
c. Expand Services and applications and select the clustered file server service.
d. Under Action, select Move this service or application to other node.
e. Click Yes to confirm the selection.
f. Repeat these steps for each file server.
g. Reboot server blade1.
4. Wait for server blade 1 to finish booting and ensure it is operating.
5. Repeat steps 1 and 2 on server blade 2. The following components are upgraded on server
blade 2:
NOTE: The component names listed match the device names that display in the FMT.
• ILO3
• BIOS
• Power Management Ctrl
• Embedded NIC – NC553i
• NC382m
• Embedded Smart Array Ctrl – P410i
• P1210m controller
• Server HDD
6. Reboot server blade 2 if required.
If the system is in a cluster, perform the following steps before rebooting. This ensures the file
system is not affected.
a. Select Windows Server Manager→Tools→Failover Cluster Manager.
b. Select the cluster. Expand the navigation tree for the cluster if it is not already expanded.
c. Expand Services and applications and select the clustered file server service.
d. Under Action, select Move this service or application to other node.
e. Click Yes to confirm the selection.
f. Repeat these steps for each file server.
g. Reboot server blade 2.
7. Wait for server blade 2 to finish booting and ensure it is operating.
Upgrading a component's firmware 73