Table 13 Known issues (continued)
ResolutionIssue
4. Navigate to the C:\hpnas\components\ directory, which contains
the WBEM installer.
5. 5. Locate and run the HPIDPWBEMPROVIDERS_X64.MSI file to re-install
the agents.
The IP address for the second node that is stored in the registry no longer
matches the second node's IP address. Change the registry key
During initial system configuration, the
Initial Configuration Tasks window may
HKEY_LOCAL_MACHINE\Software\Microsoft\OEMOOBE\indicate that there was a failure to
connect to the second node after network
settings have been changed.
RemoteNodeIpAddress to contain an IP address that the first node can
reach, preferably on the same subnet. Do not change any other values.
Verifying services are running
If an issue occurs and other troubleshooting efforts do not resolve it, verify that the following services
are always running:
• HP Alert E-Mail Startup Script
• HP Insight Event Notifier
• HP Insight Foundation Agents
• HP Insight NIC Agents
• HP Insight Server Agents
• HP Insight Storage Agents
• HP ProLiant Health Monitor Service
• HP ProLiant System Shutdown Service
• HP Remote Synchronization Service
• HP Smart Array SAS/SATA Event Notification Service
• HP Storage Management Service
• HP System Management Homepage
• HP Version Control Agent
• HP Storage Management Service
Additionally, use the following procedure to verify that the user interfaces for REST and Pool
Manager are installed and running:
1. Open IIS using one of the following methods:
• In Windows Server Manager, select IIS in the left navigation pane. In the list of servers
that display in the main content pane, right-click the applicable server and select Internet
Information Services (IIS) Manager.
• Select Internet Information Services (IIS) Manager from the Tools menu in Windows Server
Manager.
• Press Windows + R to open the Run window. Enter inetmgr and click OK.
2. Verify that the HP StoreEasy Management website contains the following entries:
• aspnet_client
• help
• rest
• webui
52 Monitoring and troubleshooting the storage system