HP ProLiant Network Adapter Software and Configuration Guide Part Number 441877-00F March 2008 (Sixth Edition)
Installation 10 1. On the desktop, click Start and select Settings > Control Panel > Administrative Tools > Computer Management to display
Installation 11 Windows 2008 x64 drivers The following Windows Server 2008 x64 network adapter drivers are used in this release: • N1G6032E.sys for
Installation 12 Components for these drivers are located in the \WIN2000 directory in the HP SoftPaq file. Adapter support on Linux The following Li
Installation 13 Parameter Options Description CheckSum = Default = ON Selections are: ON, OFF, Tx, Rx Enables or disables the transmit and
Installation 14 Parameter Options Description Jumbo = Set maximum physical receive packet Size = 18000 in the STARTUP.NCF. Choices are Jumbo = 1514
Installation 15 When an adapter configuration is saved, the NetWare install program adds load and bind statements to the autoexec.ncf file. By access
Installation 16 # BIND IPX Q57_1_E82 NET=FAFD3D25 # LOAD Q57 SLOT=2 FRAME=Ethernet_802.3 NAME=Q57_1_E83 # BIND IPX Q57_1_E83 NET=5A2D8D6D # LOAD Q
Installation 17 Where n = 10 or 100 or 1000 o Default = The adapter automatically detects network speed. • NODE. This keyword specifies a locally a
Installation 18 Advanced Network Services help - supported keywords • AGG_SELECTION o Syntax: AGG_SELECTION=[BANDWIDTH | COUNT] o Description: Set
Installation 19 • PRIMARY o Syntax: primary | secondary o Description: Identifies the primary adapter. Supported only in BIND command • PROBE_BUR
© Copyright 2005, 2008 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warra
Installation 20 o Description: Supported only after Commit command • SECONDARY o Syntax: primary | secondary o Description: Identifies the second
Firmware upgrade utility 21 Firmware upgrade utility HP Multifunction Gigabit Server Adapter Firmware Upgrade Utility The HP Multifunction Gigabit S
Firmware upgrade utility 22 • HP NC373i Multifunction Gigabit Server Adapter • HP NC373m Multifunction Gigabit Server Adapter The ccfwupg2.bat com
Firmware upgrade utility 23 where, o -i indicates the interface command o NX_NIC specifies the interface, NX_NIC, NX_NIC1, etc. (must be upper cas
Adapter configurations 24 Adapter configurations HP NC-Series 10GbE Adapters The following information describes the adapter properties available fo
Adapter configurations 25 Property Parameter Locally Administered Address Enables users or administrators to set the Locally Administered Address. T
Adapter configurations 26 Property Parameter Status Ring Size A descriptor ring size (queue size) for the status given by the network adapter to th
Adapter configurations 27 • Disabling—Each adapter can be disabled independently. Configuring multiple ports on 10GbE adapters HP multiple port ad
Adapter configurations 28 2. Execute the following command to disable PXE functionality: nxflash -i NX_NIC<Device #> --opt-rom-off Complete t
Adapter configurations 29 Troubleshooting Unable to boot host system on Windows or Linux Problem: Unable to boot the host system with the network ad
Contents 3 Contents Overview...
Adapter configurations 30 HP NC-Series Broadcom adapter properties • Flow Control. The Flow Control property allows the user to enable or disable t
Adapter configurations 31 o 1 Gb Full Auto. Sets the speed to 1 Gbps and mode to Full-Duplex o 10 Mb Full. Sets the speed to 10 Mbps and mode to F
Adapter configurations 32 Windows Server 2003 and Windows Server 2003 x64 configurations Although the default values should be appropriate in most c
Adapter configurations 33 • Speed & Duplex. The Speed & Duplex property allows the user to set the connection speed to the network and mode
Adapter configurations 34 o None. Disables checksum offloading o Rx TCP/IP Checksum. Enables receive TCP, IP, and UDP checksum offloading o Tx TC
Adapter configurations 35 the type of frame that will cause the adapter to wake up, select the appropriate option from the Value drop-down list on t
Adapter configurations 36 o Default for NC6170 and NC7170 adapters = No Action o Range for NC6170 and NC7170 adapters = Disabled; Enabled; Hardwar
Adapter configurations 37 • Locally Administered Address. Specifies the user-defined MAC Address of the adapter, which overrides the burned-in MAC
Adapter configurations 38 for auto-negotiation. If this feature is on, and the speed is not set to auto-negotiation, the driver will wait for a shor
Adapter configurations 39 o Auto. (Default) Auto detect flow control o Disable. PAUSE frame receipt and transmission is disabled o Tx PAUSE. PAUS
Contents 4 Technical support...
Adapter configurations 40 o Range = Off; On • Offload Transmit TCP Checksum. Offloads the task of computing the checksum for outgoing TCP or UDP
Adapter configurations 41 Boot Agent The Intel® Boot Agent is a software product that allows your networked client computer to boot using a program
Adapter configurations 42 To customize the behavior of the Boot Agent software in a pre-boot PXE or RPL environment complete the following steps: 1
Adapter configurations 43 Configuration settings Possible values Description Show Setup Prompt • Enabled • Disabled Controls whether or not the B
Adapter configurations 44 Use IBAUtil to enable or disable WOL or Boot Agent features. To obtain this utility download the HP ProLiant Networking So
Adapter configurations 45 Parameter Description -UPGRADE or -UP Downloads the Boot Agent stored within IBAUtil to the adapters in the system. -FLAS
Adapter configurations 46 • 2–Invalid adapter • 3–Bad command line parameter • 4–EEPROM checksum failure • 5–EEPROM read failure • 6–EEPROM wri
Adapter configurations 47 • PXE-E01: PCI Vendor and Device IDs do not match! Image vendor and device ID do not match those located on the card. Be
Adapter configurations 48 • PXE-EC1: Base-code ROM ID structure was not found. No base code can be located. An incorrect flash image is installed o
Adapter configurations 49 If you are having problems with the local (client) or network operating system, contact the operating system manufacturer
Overview 5 Overview Supported adapters and operating systems The following is a list of HP NC-Series adapters that are supported on HP ProLiant serve
Adapter configurations 50 team members. After you press the D key, the information remains displayed until you reboot your computer. Actual diagnost
Adapter configurations 51 o Range = 1–32 • Flow Control Settings. The Flow Control property allows the user to enable or disable the receipt or t
Diagnostics 52 Diagnostics HP NC-Series NetXen 10GbE diagnostics Please note that network traffic will be interrupted while you are running diagnosti
Diagnostics 53 For CX4 (copper interface) applications an external module is required to connect the four transmit lanes to the four corresponding re
Diagnostics 54 This tests the external link connection. For the fiber medium, this is simply another external loopback test. For the copper medium, t
Diagnostics 55 • C6. NVM access and reset-corruption tests This tests the non-volatile memory access (both read and write). It also tests for approp
Diagnostics 56 • D6. RPC test (D06) This test checks the receive catch-up path by sending packets to a different Tx chain. The packets will go throu
Diagnostics 57 o Pseudo random data test: A pre-calculated pseudo random data is used to write a unique data into each test RAM. After the first pas
Diagnostics 58 The content of VPD is saved first before performing the test. After it is saved, the test writes one of the five pattern test data, 0x
Diagnostics 59 • Test aborted by user • Tx DMA:Got 0x%08x @ 0x%08x. Expected 0x%08x • Rx DMA:Got 0x%08x @ 0x%08x. Expected 0x%08x • Tx DMA failed
Overview 6 • HP NC7770 PCI-X Gigabit Server Adapter • HP NC7771 PCI-X Gigabit Server Adapter Embedded adapters: • HP NC105i PCIe Gigabit Server Ad
Diagnostics 60 • File size %d is too big, max is %d • Invalid %s • Failed writing 0x%x to 0x%x • *1 • *1 • *1 • *1 • Cannot perform task whil
Diagnostics 61 3. Type DIAGS and press the Enter key. The test utility program automatically scans the hardware and lists all supported adapters. If
Diagnostics 62 The Display Diagnostic Log option allows you to view a detailed report of the tests you just ran. When Diagnostic Log is enabled, test
Technical support 63 Technical support Before you contact HP Be sure to have the following information available before you call HP: • Technical su
Technical support 64 • Navigate to a specific product, and then look for support information from the list of support resources at the HP support w
Acronyms and abbreviations 65 Acronyms and abbreviations BIOS Basic Input/Output System DHCP Dynamic Host Configuration Protocol IPL initial progr
Acronyms and abbreviations 66 UNDI Universal Network Driver Interface
Index 67 B Boot Agent 41 C configuration 24, 50 D diagnostics 52, 53, 56, 60 Diver and software information 7 F Firmware upgrade 21, 22 I i
Overview 7 • Windows Server 2003 x64 Editions • Windows® 2000 (NDIS5) • DOS NDIS2* NetWare • NetWare 6.5 Server • NetWare 6.6 Server • NetWare
Overview 8 • Microsoft® Windows Server 2008 \WIN2008x64 • Microsoft® Windows Server 2003 \WIN2003 • Microsoft® Windows Server 2003 x64 \WIN2003x64
Installation 9 Installation Downloading files 1. Go to the HP website (http://www.hp.com). 2. Click Software & Driver Downloads from the left m
Kommentare zu diesen Handbüchern