HP 3PAR Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Software HP 3PAR herunter. HP 3par User's Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 89
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
HP 3PAR VMware ESX Implementation
Guide
Abstract
This implementation guide provides information for establishing communications between an HP 3PAR StoreServ Storage and
a VMware ESX host. General information is also provided on the basic steps required to allocate storage on the HP 3PAR
StoreServ Storage that can then be accessed by the ESX host.
HP Part Number: QL226-97063
Published: September 2013
Seitenansicht 0
1 2 3 4 5 6 ... 88 89

Inhaltsverzeichnis

Seite 1 - Abstract

HP 3PAR VMware ESX ImplementationGuideAbstractThis implementation guide provides information for establishing communications between an HP 3PAR StoreS

Seite 2

2. To create host definitions, issue the createhost command with the -persona option tospecify the persona and the host name.For HP 3PAR OS 3.1.1 or e

Seite 3 - Contents

NOTE: For configurations that are intended to have more than one host type (for example, anESX host and a Windows host) connected to a shared HP 3PAR

Seite 4 - 4 Contents

Creating the Host DefinitionBefore connecting the ESX host to the HP 3PAR StoreServ Storage, create a host definition for eachHP 3PAR StoreServ Storag

Seite 5 - Contents 5

You can set up fabric zoning by associating the device World Wide Names (WWNs) or the switchports with specified zones in the fabric. Although you can

Seite 6 - 1 Introduction

3.0.2 or later, verify that each switch port is in the correct mode using the Brocade telnetinterface and the portcfgshow command, as follows:brocade2

Seite 7 - Audience

◦ HP 3PAR HBA 4G: 1638◦ HP 3PAR HBA 8G: 3276 (HP 3PAR StoreServ 10000 and HP 3PAR StoreServ 7000systems only)• The I/O queues are shared among the con

Seite 8

In HP 3PAR Storage arrays with more than two nodes, failover behavior occurs on node pairs;that is, if node 0 goes down, ports on node 0 fail over to

Seite 9

Before Persistent Ports is active, the output of the showhost command displays as follows:# showhostId Name Persona ---------------WWN/iSC

Seite 10

3 Configuring the HP 3PAR StoreServ Storage for iSCSIThis chapter explains how to establish an iSCSI connection between the HP 3PAR StoreServ Storagea

Seite 11 - Setting Up the Ports

3. Issue the HP 3PAR OS CLI showport -iscsi command to check the current settings of theiSCSI ports:# showport -iscsiN:S:P State IPAddr Netmask Gat

Seite 12 - Creating the Host Definition

© Copyright 2013 Hewlett-Packard Development Company, L.P.Confidential computer software. Valid license from HP required for possession, use or copyin

Seite 13 - HP 3PAR Coexistence

ESX/ESXi uses the generic legacy host persona of 6 for HP 3PAR OS 3.1.1 or earlier. As of HP3PAR OS 3.1.2, a second host persona 11 (VMware), which en

Seite 14 - ◦ Emulex 4G: 959

ports must have been set up and an iSCSI connection/session must be established. The iSCSIconnection/session is established by following the steps in

Seite 15 - HP 3PAR Priority Optimization

The following example uses the CHAP secret (CHAP password) host_secret3 for the ESXhost. Be aware that the CHAP secret must be at least 12 characters

Seite 16

Figure 2 CHAP Credentials in ESX/ESXi 4.x or ESX/ESXi 5.x3. Enter the CHAP Secret (must be at least 12 characters long). Use the same secret that youe

Seite 17 - Unsupported Configurations

5. Click OK again to confirm.6. On the HP 3PAR StoreServ Storage, issue the HP 3PAR OS CLI sethost command with theinitchap parameter to set the CHAP

Seite 18 - Software iSCSI Support

Figure 3 CHAP Credentials in ESX 4.x and 5.xIssue the HP 3PAR OS CLI showhost -chap command to verify that the specified CHAPsecret has been set for t

Seite 19 - OS 3.1.x and OS 2.3.x

2. Press Ctrl+S to enter the utility.Figure 4 iSCSI Utility3. Select a controller and press Enter.4. From the Controller Configuration screen, select

Seite 20 - OS 2.2.x

1. After entering the iSCSI Initiator Configuration screen, which will be the first screen displayed,obtain the IQN for the card and create a host def

Seite 21

11. If you do not want to use CHAP as an authentication method, exit the CN1100E setup screensand reboot now.If you would like to use CHAP as an authe

Seite 22

Figure 9 CHAP Configuration for Mutual CHAPFill in the Target CHAP Name (the initiator IQN name), the Target Secret, the InitiatorCHAP Name (which is

Seite 23 - Software iSCSI Support 23

Contents1 Introduction...6Supported Configurations...

Seite 24

Target Port Limits and SpecificationsTo avoid overwhelming a target port and ensure continuous I/O operations, observe the followinglimitations on a t

Seite 25 - Hardware iSCSI Support

4 Configuring the HP 3PAR StoreServ Storage for FCoESetting Up the FCoE Switch, FCoE Initiator, and FCoE target portsConnect the ESX host FCoE initiat

Seite 26

NOTE: If changing the config from iSCSI to FCoE, follow the steps below.1. Issue the showportcommand.# showport0:3:1 target ready - 000E1E05B

Seite 27

Creating the Host DefinitionBefore connecting the ESX host to the HP 3PAR StoreServ Storage, a host definition needs to becreated that specifies a val

Seite 28

Use showhost -persona to show the persona name and Id relationship.# showhost -personaId Name Persona_Id Persona_Name Persona_Caps0 E

Seite 29

5 Configuring the Host for a Fibre Channel ConnectionThis chapter describes the procedures and considerations that are required to set up an ESX hostt

Seite 30

To change Path TOV value (repeat for all ports) follow the example below. Also this command canbe included in ESX host startup such that it will be ru

Seite 31

NOTE: VMware and HP recommend the LSI logic adapter emulation for Windows 2003 Servers.The LSI Logic adapter is also the default option for Windows 20

Seite 32

Fibre Channel” (page 39) for procedures on implementing and configuring the round-robin pathpolicy on ESX/ESXi 4.0 and later with an HP 3PAR StoreServ

Seite 33

• A path policy of MRU (most recently used) does not maintain or reinstate balancing of I/Oload after a failover/failback multipath event. This could

Seite 34

Script Alternative for Path Policy Changes on Storage Devices without a Host Reboot...46Performance Considerations for Multiple Host Config

Seite 35

Figure 10 LUN Set to Round RobinManaging a round robin I/O path policy scheme through the VI/vSphere client GUI for a largenetwork can be cumbersome a

Seite 36

NOTE:• SATP rule changes cannot be affected through vSphere GUI.• SATP rule changes through esxcli commands populate the esx.conf file.• A custom SATP

Seite 37

ESX/ESXi 4.0 GA - 4.0 UxNOTE:• Though ESX 4.0 GA - 4.0 Ux supports custom SATP rules, the -P options for setting PSP (pathpolicy) within the custom ru

Seite 38

CAUTION: The procedure for changing the default SATP rules to use the round robin I/Omultipathing policy is intended to apply only to VMware hosts usi

Seite 39

To remove the above Active-Active custom SATP rule:# esxcli storage nmp satp rule remove -s "VMW_SATP_DEFAULT_AA" -P "VMW_PSP_RR"

Seite 40

SATP Custom Rules and Associated Defined ParametersTo list SATP custom rules and associated defined parameters, issue the following commands:ESXi 5.x

Seite 41 - ◦ VMW_PSP_MRU

ESX/ESXi 4.x exampleThe command is the same for ESX/ESXi 4.x. The output shown is for ESX 4.0:# esxcli nmp device listnaa.50002ac000b40125 Device D

Seite 42 - ESX/ESXi 4.0 GA - 4.0 Ux

ESX/ESXi 4.x# esxcli nmp device list -d naa.50002ac0005800acNOTE: If I/O is active to a LUN and an attempt is made to modify the path policy, a failur

Seite 43 - ESXi 5.x

VMware ESX Release 3.5 Update 4 through ESX 4.x and ESXi 5.0As of VMware ESX release 3.5 update 4, and including ESX 4.0 GA and ESX 4.1 (with all ESX4

Seite 44 - SATP Info Commands

Follow-up Actions/Recommendations for ESX 3.5 Update 3 and EarlierThe behavior of the HP 3PAR StoreServ Storage port being overrun is limited only to

Seite 45 - Show Device Information

HP 3PAR documentation...85Typographic conventio

Seite 46

Example 2 (set up as follows):• LSI 2G FC HBA installed on the HP 3PAR StoreServ Storage• 12 ESX hosts attached to a LSI port on the HP 3PAR StoreServ

Seite 47 - Storage Array

3. Make a backup copy of /etc/vmware/esx.conf.cp /etc/vmware/esx.conf /etc/vmware/esx.conf.orig4. Identify the QLogic HBA module that is currently loa

Seite 48 - VMware ESXi Release 5.1

ESX extensions that make use of these primitives are collectively referred to as vStorage APIs forArray Integration (VAAI). The VMware primitives enab

Seite 49 - port queue depth

NOTE: VAAI Plugin 2.2.0 is required if the ESXi 5.x server is connected to two or more arraysthat are running a mix of OS HP 3PAR OS 2.3.1.x and OS 3.

Seite 50

additional disk space is added, use the Retry option on the warning message to bring the VMback to the read-write state. If you select the Cancel opti

Seite 51 - Storage I/O Control

Figure 11 Virtual Machine Message — Retry and Cancel optionsAdditional New Primitives Support on ESXi 5.xHP 3PAR OS 3.1.1 or later supports additional

Seite 52

VAAI Plugin VerificationNOTE: VAAI Plugin 2.2.0 must be installed if an ESXi 5.x server is connected to two or morearrays that are running a mix of HP

Seite 53

• On ESX 4.1, you can verify that the VAAI Plugin is installed and enabled on devices usingthe following commands:• To show the version of the install

Seite 54

Figure 12 Hardware Acceleration for HP 3PAR devicesVMware All Paths DownAll Paths Down (APD), a feature of the VMware ESXi host used in cases where al

Seite 55

6 Configuring the Host as an FCoE Initiator Connecting toa FC target or an FCoE TargetAll contents of the Fibre Channel section of this guide apply to

Seite 56 - VAAI Plugin Verification

1 IntroductionThis implementation guide provides information for establishing communications between anHP 3PAR StoreServ Storage and a VMware ESX host

Seite 57

Figure 13 Configuring FCoE2. In the System Options pane, select NIC Personality Options.Figure 14 NIC Personality Options3. In the PCI Slot 2 Pane, se

Seite 58 - VMware All Paths Down

Figure 15 Configuring the PCI Slots4. PCI Slot 2 Port 1 and Port 2 now display FCoE.Figure 16 PCI Slot 1 and Slot 2 Configured for FCoE5. Save the cha

Seite 59 - Configuring the FCoE Switch

Figure 17 Exiting the BIOS UtilityConfiguring an HP 3PAR StoreServ Storage Port for a FCoE HostConnectionWhen setting up FCoE initiator to FC target,

Seite 60 - Figure 13 Configuring FCoE

Figure 18 Initiator FCoE to FC TargetNOTE: For complete and detailed instructions for configuring a server with a given ConvergedNetwork Adapter, refe

Seite 61

Figure 19 Initiator FCoE to Target FCoE1. Install the CNA card in the server just like any other PCIe card - refer to the server vendordocumentation.2

Seite 62 - Connection

7 Configuring the Host for an iSCSI ConnectionThis chapter describes the procedures for setting up an ESX software iSCSI configuration with anHP 3PAR

Seite 63

NOTE: When multiple teamed NICs are configured, all HP 3PAR StoreServ Storage iSCSI portsand ESX iSCSI NICs must be in the same VLAN of the IP switch.

Seite 64

Installing Virtual Machine Guest Operating SystemThe VMware ESX documentation lists recommended virtual machine guest operating systems (GOS)and their

Seite 65

3. Click the Add Networking Link. The Add Network wizard appears.4. Select VMkernel and click Next. This lets you connect to the VMkernel which runs s

Seite 66

8. Click OK to complete.NOTE: HP recommends an Active/Active NIC Teaming configuration for best failoverperformance. NIC Teaming however, is not suppo

Seite 67 - Creating a VMkernel Port

HP 3PAR OS Upgrade ConsiderationsFor information about planning an online HP 3PAR Operating System (HP 3PAR OS) upgrade, seethe HP 3PAR Operating Syst

Seite 68

10. Enter a network label. Click Next.11. Specify the IP settings that will be used for the iSCSI network. Click Next.12. Review the information. Clic

Seite 69 - 9. Click Next

5. Enter the Network Label and IP address for the Service console used to communicate with theiSCSI software initiator. The IP address must be in the

Seite 70

9. Check the Configuration display.The new network configuration is displayed with the addition of the iSCSI network.You should now be able to ping th

Seite 71 - 7. Click Finish

4. In the ESX host, select the Configuration tab. Then select iSCSI Software Adapter in StorageAdapter.5. Click the Properties tab.6. Select the Gener

Seite 72

11. Click Add...12. Enter the IP address of one of the previously defined HP 3PAR StoreServ Storage iSCSI ports.13. Click OK.14. Add additional HP 3P

Seite 73

15. When all of the desired HP 3PAR StoreServ Storage iSCSI ports have been added to theDynamic Discovery tab, close this window.Configuring the VMwar

Seite 74 - 13. Click OK

16. Reboot the ESX host. If virtual machines are active, shut them down or suspend them.The ESX host and HP 3PAR StoreServ Storage should now be confi

Seite 75

NOTE: If you are running W2K8 VM Cluster with RDM-shared LUNs, then individually changethese specific RDM LUNs from Round Robin policy to Fixed Path p

Seite 76 - # showhost

8 Allocating Storage for Access by the ESX HostThis chapter describes the basic procedures that are required to create and export virtual volumesso th

Seite 77

Creating Virtual Volumes for HP 3PAR OS 2.2.3 or EarlierWhen running HP 3PAR OS 2.2.3 or earlier, the createaldvv command can be used to createvirtual

Seite 78 - Using the HP 3PAR OS CLI:

2 Configuring the HP 3PAR StoreServ Storage for FibreChannelThis chapter explains how to establish a Fibre Channel connection between the HP 3PAR Stor

Seite 79 - Exporting LUNs to an ESX Host

http://www.hp.com/go/bscConcerning TPVVs, ESX VMFS-3 does not write data to the entire volume at initialization and itcan be used with TPVVs without a

Seite 80 - Creating a VLUN for Export

Consult the HP 3PAR Management Console Users Guide and the HP 3PAR Command Line InterfaceReference for complete details on exporting volumes and avail

Seite 81 - Removing Volumes

Figure 20 Detaching a LUNHost and Storage UsageEventlog and Host Log MessagesAll HP 3PAR system debug messages can be seen using the showeventlog -deb

Seite 82 - Host and Storage Usage

At an interval of every 5 minutes, an ESX host such as ESXi 5.x sends REPORT LUN commandsand discovers any new LUNs.On ESXi 5.x, the following vmkerne

Seite 83 - Host and Storage Usage 83

9 Booting the VMware ESX Host from the HP 3PAR StoreServStorageThis chapter provides a general overview of the procedures that are required to boot th

Seite 84

10 Support and Other ResourcesContacting HPFor worldwide technical support information, see the HP support website:http://www.hp.com/supportBefore con

Seite 85 - HP 3PAR documentation

See:For information about:HP 3PAR-to-3PAR Storage Peer Motion GuideMigrating data from one HP 3PAR storage system to anotherHP 3PAR Secure Service Cus

Seite 86

See:For information about:Planning for HP 3PAR storage system setupHardware specifications, installation considerations, power requirements, networkin

Seite 87

Typographic conventionsTable 4 Document conventionsElementConventionBold text• Keys that you press• Text you typed into a GUI element, such as a text

Seite 88 - HP 3PAR branding information

11 Documentation feedbackHP is committed to providing documentation that meets your needs. To help us improve thedocumentation, send any errors, sugge

Seite 89 - 11 Documentation feedback

2. If the port has not been configured, take the port offline before configuring it for the ESX hostby issuing the following HP 3PAR OS CLI command:co

Kommentare zu diesen Handbüchern

Keine Kommentare