Table 13 Known issues (continued)
ResolutionIssue
The use of this registry key is documented at http://support.microsoft.com/
kb/824344.
iSCSI Software Target service
on MACHINE_NAME. Error 1053:
The service did not respond
to the start or control
request in a timely manner.
The UID LED cannot be enabled or disabled in the System Management
Home page until the Enclosure Manager key has been generated. The
Enclosure Manager key can be generated using the System Manager snap-in.
The Enclosure UID page that is part of
the HP System Management Homepage
cannot be used to enable or disable the
UID status LED.
The reboot time for the network storage system is approximately six to seven
minutes.
Length of network storage system reboot
time
This issue can be resolved by doing one of the following:A cluster network interface reports status
(from cluster net or cluster
• Allow 12–24 hours to pass for the Microsoft Failover Cluster Manager to
resolve the issue automatically.
netint command or Failover Cluster
Manager) as “network partitioned” when
• Manually restart the node that was restarted or affected.
a cluster node is rebooted and rejoins
the cluster. The network interface is still
• Manually disable or enable the NIC on the affected cluster node that is
causing the issue, under Network Connections.
usable for communications to other
nodes; it is only the communications
between the cluster nodes that is
affected. The cluster interface status will
change after 12–24 hours. This issue is
intermittent and takes approximately
30–50 reboots of a node to reproduce.
FSRM only configures its config store in the cluster database when the FSRM
service starts. To resolve this issue, reboot one node in the cluster, or you
One of the following occurs:
• File Server Resource Manager (FSRM)
displays the error message:
File Server Resource
Manager global
can start/stop the FSRM services by issuing the following commands on the
command line using elevated privileges:
net stop srmsvc
net stop srmreports
configuration cannot be
accessed since it is not
installed yet.
net start srmreports
net start srmsvc
• A corrupted FSRM file causes the
following error message to display
This issue is documented by Microsoft at:
on the Quota window of the
Windows New Share wizard:
No quota templates are
available on this server.
http://technet.microsoft.com/en-us/library/gg214171(WS.10).aspx
The HP StoreEasy 5000 Storage does not have a VDS Hardware Provider,
so the Diskraid utility does not work.
The Diskraid utility does not operate with
the HP StoreEasy 5000 Storage.
HP strongly recommends using Active Directory or other RFC2307 compliant
LDAP stores for NFS user name mapping. Using Active Directory Lightweight
The NFS user mapping should not use
ADLDS.
Data Services (ADLDS) is not recommended. Configuring ADLDS in a clustered
environment is beyond the scope of this document.
The Onboard Administrator GUI Launch button only applies to systems with
the c3000/c7000 chassis. You are not able to use this button with the HP
StoreEasy 5000 Storage .
The Onboard Administrator GUI cannot
be launched from the Integrated
Lights-Out 3 page. The Launch button is
in the Active Onboard Administration
section under the BL c-Class node in the
Integrated Lights-Out 3 navigation tree.
Update the SAS I/O module firmware again. If the second update is
unsuccessful, review the log file for more information.
On rare occasions, an update to the SAS
I/O module firmware may result in the
following message: Flash failed
for xxxx half of SAS I/O
Module. Check log file yyyy
Known issues 47