Restrictions
This command functions only if the enclosure power is already on. Because the EMU hardware
cannot determine if a blade is physically present unless enclosure power is on, the EM reports the
warning “enclosure power is off” if this command is issued when power is off.
Enclosure control
The commands in the section provide various enclosure control functions.
DOWNLOAD CONFIG
Syntax
DOWNLOAD CONFIG <URL>
Description
Downloads a previously saved configuration script file from a specific IP host then executes it. This
command should be used to recover configuration after replacement of a failed EMU.
Supported protocols are HTTP, FTP, and TFTP. The URL should be formatted asprotocol://host/
path/file. If your FTP server does not support anonymous connections, you can specify a
username and password by replacing the host part in the above format with
username:password@host.
Restrictions
Only IPv4 is supported in EM 1.0 or later.
POWEROFF ENCLOSURE
Syntax
POWEROFF ENCLOSURE
Description
The EM removes main DC power from the enclosure (just as if the user had pressed the enclosure
power-button. Servers are NOT automatically sent a graceful shutdown command; that should be
done prior to issuing this command using POWEROFF SERVER. Except when in script mode, the
user is prompted for an explicit confirmation, which must be given, or the command is terminated.
Restrictions
None
POWERON ENCLOSURE
Syntax
POWERON ENCLOSURE
Description
The EM sends a command to the health monitor to enable main DC power (just as if the user had
pressed the enclosure power button).
Restrictions
None