HP SP750 - Professional - 256 MB RAM Spezifikationen Seite 180

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 200
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 179
162
Verify Analysis Program Submittal From MSC.Patran. The session file you ran
did not submit the model to an analysis program (for example, ABAQUS,
MSC.Nastran, etc.). If you have an analysis program available locally or remotely,
follow these steps to test the analysis link:
1. Configureanalysisenvironment variablesin site-setup.Themscsetuputility
should have done this install. See Environment Variables (p. 92) for more
information.
2. Reopen the test_interface.db file in MSC.Patran, by selecting Open
Database under the File menu.
3. Disable Analysis Manager by entering the following command at the
command prompt (the bottom line on the main MSC.Patran form):
analysis_manager.disable
4. Choose Analysis from the MSC.Patran main form. The Analysis form
appears. Make sure “Action” is set to Analyze, “Object” is set to Entire
Model, and “Method” is set to Full Run.
5. Press Select Load Cases (Select Subcase for some preferences). A form titled
Select Load Cases appears (Subcase Select for some preferences). If the
“Default” load case appears under Selected Load Cases, press OK to close
the form. If the “Default” load case only appears under Available Load
Cases, cursor pick “Default” and then press OK.
6. Press Apply on the Analysis form.MSC.Patran executes the interfaceagain,
but it also submits the model to the analysis program.
7. When the job completes, check the output from the analysis code to confirm
that the analysis completed successfully. For example, the output file for
MSC.Nastran will be
test_interface.f06.
ops_manual.book Page 162 Friday, July 27, 2001 12:07 PM
Seitenansicht 179
1 2 ... 175 176 177 178 179 180 181 182 183 184 185 ... 199 200

Kommentare zu diesen Handbüchern

Keine Kommentare