(cont.) 3. Thevendordaemonis not running.Boththe lmgrd and msc
daemons must be running on the server. Check the
lmgrd.log filetodetermine whylmgrddid notstartmsc and
ensure that the VENDOR line includes the correct path, etc.
4. The client does not recognize the hostname on the SERVER
line or set with MSC_LICENSE_FILE. Make sure that the
local machine can ping or rsh to “host”. Also, try the telnet
test below.
5. The network is down. Same as above.
6. You are running the license file on the server in an old
version of FLEXlm. MSC.Patran requires at least FLEXlm
v6.0 (the version shipped with MSC.Patran).
7. TCP is not running properly on the client or host. See
Resolution #6 on page 118 for more information on
installing TCP/IP under Windows NT.
8. The port selected in the license.dat file and the port given to
MSC.Patran via MSC_LICENSE_FILE are not the same, or
the port is being used by something else.
Youcantest TCPaccess toahostandportwith thefollowing
telnet command:
% telnet <hostname> <portnum>
9. Note that this will not allow you to login (
telnet is not
actually listening at that port), but it should connect.