124
6.3 Import/Export, Analysis Submit and Online
Documentation
This section covers errors that occur when MSC.Patran interacts with external
software.This includesimportingor exportingofneutral files,databases,resultsfiles,
etc. It also includes connection with analysis packages (submitting analysis) and
problems with the FrameViewer online documentation system.
Problem 1:
Any
Analysis not submitted from within MSC.Patran
I select Analysis|Analyze|Full Run to submit a job to ABAQUS or
MSC.Nastran, but MSC.Patran does not submit the analysis.
Resolution1:
Make sure you have defined the appropriate MSC.Patran Application
environment variables - see Environment Variables (p. 92). Or on
Windows NT check the settings in the p3_trans.ini file - see
Customizing Analysis Preferences in p3_trans.ini (p. 80).
Problem 2:
Any
“Write failed: file system full” when submitting analysis
When I attempt to import my analysis results into MSC.Patran using
the Analysis menu pick, I get the following error:
write failed: file system full: directory /tmp
Resolution2:
This means the disk space for /tmp is too small to import the analysis
results into MSC.Patran. Either increase the disk space allocated for
/tmp, or use the environment variable TMP to redirect MSC.Patran to
another larger scratch directory location. See Environment Variables
(p. 92) for more information.
Problem 3:
Any
Unable to locate command when submitting analysis
When I submit my model for analysis in MSC.Patran Thermal or
MSC.Patran Advanced FEA, it fails because it could not find a specific
command.
Resolution3:
Make sure your command search path includes
<installation_dir>/bin or <
inst
>/patran
nn
/bin.
ops_manual.book Page 124 Friday, July 27, 2001 12:07 PM