Service Calibrations
4-18 HP Designjet T Series — Service Manual
Recovery through the Front Panel and retry the Printhead Alignment.
10 Once the complete Line Sensor calibration is completed successfully, OK will
be dis
played on the Front Panel.
Carriage PCA
The purpose of this Service Calibration is to reset the ink short thresholds
after replacing the Carriage PCA. This calibration is integrated into the Scan
Axis diagnostic test. See
4. Carriage Assembly on page 3-26.
Perform the Carriage Setup as follows:
1 In
the Service Calibrations submenu, scroll to Carriage PCA and press OK.
2 To calibrate the Carriage PCA, run the Carriage Assembly diagnostic test.
See
4. Carriage Assembly on page 3-26.