Service Calibrations
4-14 HP Designjet T Series — Service Manual
and press OK.
2 In the Drop Detector Calibration submenu, scroll to Calibrate Drop
Detector and press OK.
3 When the following message appears on the front panel, you must select
whether you would like to continue with the calibration by pressing the OK
key. Press Back or Cancel to exit the calibration.
4 The Printer will start to calibrate the Drop Detector.
5 Once the Drop Detector has been calibrated, the results will be displayed on
the Front Panel. Press OK to finish the calibration.