Modems 5-41
Meridian MAX
Installation Guide
Product release 8
UDS 2440
Figure 5-10 shows the front and rear view of the UDS 2440 dial-up
supervisor modem.
The UDS 2440 modem does not contain any internal switch settings.
Complete Procedure 5-8 to configure the UDS 2440 modem for dial-up
supervisor.
Meridian MAX automatically configures remote supervisor modems
connected at the Meridian MAX end.
The cable connecting the Meridian MAX SNN/SNN-E’s VME multiport
cable and the UDS 2440 modem is the modem cable NT7D99AA.
The cable connecting the Meridian MAX IPE/IPE-E’s VME multiport
cable and the UDS 2440 modem is the modem cable NT1R03HF.
Procedure 5-8
Configuring the UDS 2440 modem for dial-up supervisor—remote end
1 Connect a workstation to the modem with a straight-through NT1R03Dx
or NT1R03Ex cable. Set the workstation speed to 2400 baud.
2 Connect the workstation and the modem to their power sources. Make
sure the modem is connected to the telephone system with an RJ-11
cable/connector.
3 Power up the workstation and the modem.
4 Enter the following commands on the workstation keyboard, pressing
{ENTER} after each command.
5 Enter atz followed by {RETURN}.
OK
6 Enter at&f followed by {RETURN}.
OK
7 Enter ats0=1 followed by {RETURN}.
OK
8 Enter at&d3 followed by {RETURN}.
OK
9 Enter at&s1 followed by {RETURN}.
OK