Edit an OXPd quota agent record
1. Go to Tools > Options > Device Management > Conguration > OXPd Quota Agents.
2. Select the OXPd quota agent record from the list, and then click the Edit button. The Quota Agent Details
window opens.
3. In the Name box, enter an unlocalized name for the OXPd quota agent record (maximum of 100
characters).
4. In the Quota agent section, use the following steps to specify the settings that the device requires to access
the OXPd quota server:
a. In the URI box, enter the URI of the OXPd quota server (maximum of 256 characters). The URI is case-
sensitive and must begin with one of the following protocols:
http://
https://
le://
ftp://
This text box can use static data or custom variables supported in the following formats:
Variable data (a variable always starts and ends with %% with the name of the variable in
between the starting and ending %% signs)
%%<custom variable>%% (where “<custom variable>” is the name of the user dened eld)
Example: %%var_URI%%
Variable data along with a combination of static content before or after the variable
<static value>%%<custom variable>%%<static value>
Example: https://%%var_URI%%
Example: https://%%var_URI%%/myApp
TIP: By starting the variable data name with var_, it’s easier to nd and identify user dened elds in
HP Web Jetadmin.
TIP: For more information on variable data, see Create and Use Variable Data on page 183.
b. If network credentials are required to access the OXPd quota server, select the Use credentials check
bo
x. Enter the network credentials in the User name (maximum of 128 characters), Password
(maximum of 128 characters), and Conrm password boxes.
c. In the Connection timeout box, enter the maximum number of seconds that the device has to
e
stablish a connection to the OXPd quota server before a timeout occurs.
d. In the Response timeout
box, enter the maximum number of seconds that the device has to receive a
response from the OXPd quota server before a timeout occurs.
e. In the Retry interval box, specify the number of seconds that the device waits before trying to connect
t
o the OXPd quota server again.
f. In the Max consecutive retries box, enter the maximum number of times that the device tries to
c
onnect to the OXPd quota server.
5. In the Quota StartJob User Prompt Target
section, use the following steps to specify the settings for the
web resource that is displayed in a web browser when a user initiates a job on the device:
ENWW Device Management Conguration Options 77