Event Reporting: Templates and Codes D85
ASC/ASCQ Codes
Table D7 lists HSG80-specific SCSI ASC and ASCQ codes. These
codes are Template-specific and appear at byte offsets 12 and 13.
Note Additional codes that are common to all SCSI devices can be
found in the SCSI specification.
Table D7 ASC and ASCQ Codes
ASC Code ASCQ Code Description
04 80 Logical unit is disaster tolerant failsafe locked (inoperative).
3F 85 Test Unit Ready or Read Capacity Command failed
3F 87 Drive failed by a Host Mode Select command.
3F 88 Drive failed due to a deferred error reported by drive.
3F 90 Unrecovered Read/Write error.
3F C0 No response from one or more drives.
3F C2 NV memory and drive metadata indicate conflicting drive configurations.
3F D2 Synchronous Transfer Value differences between drives.
80 00 Forced error on Read
82 01 No Command control structures available.
84 04 Command failed - SCSI ID verification failed.
85 05 Data returned from drive is invalid.
89 00 Request Sense command to drive failed.
8A 00 Illegal command for pass through mode.
8C 04 Data transfer request error.
8F 00 Premature completion of a drive command.
93 00 Drive returned vendor unique sense data.
A0 00 Last failure event report.
A0 01 Nonvolatile parameter memory component event report.
Seitenansicht 518