Event Reporting: Templates and Codes D37
HW
This hardware/software flag is located at byte offset 104, bit 7. If this
flag is equal to 1, the unrecoverable condition is due to a hardware-
detected fault. If this flag is equal to 0, the unrecoverable condition is
due to an inconsistency with the software, or an intentional restart or
shutdown of the controller was requested.
Restart Code
Located at byte offset 104, bits 4-6, the Restart Code describes the
actions taken to restart the controller after the unrecoverable condition
was detected. Table D2 gives a description of restart codes and their
descriptions.
Parameter Count
The Parameter Count, located at byte offset 104, bits 0-3, indicates the
number of Last Failure Parameters containing supplemental
information supplied.
Repair Action
The Repair Action found at byte offset 105 indicates the recommended
repair action code assigned to the event. This value is used during
Symptom-Directed Diagnosis procedures to determine what
notification/recovery action should be taken. For more details, see
Recommended Repair Action Codes, page D77.
Error Numbers
Located at byte offset 106, the Error Number, when combined with the
value contained in the Component ID field, uniquely-identifies the
condition detected.
Table D2 Controller Restart Codes
Restart Code Description
0 Full software restart
1No restart
2 Automatic hardware restart