Hp Array Controller HSG V8.7 Software Bedienungsanleitung Seite 404

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 576
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 403
B132 HSG80 Users Guide
Specify NODESTROY_UNFLUSHABLE_DATA to leave the
unwritten data intact in the failed controllers write-back cache. When
the failed controller is replaced and placed into service, the write-back
cache data is flushed to the appropriate devices.
Specify DESTROY_UNFLUSHABLE_DATA to reconfigure the
operational controller before replacing the failed controller. The
unwritten data of the failed controller may reference devices not present
in the new configuration. If you do not destroy the old configuration
data, it may conflict with the new configuration and cause the
subsystem to behave unpredictably.
Caution Unflushed data cannot be recovered after it is destroyed.
Example
This example shows how to terminate failover mode between two
controllers in a dual-redundant configuration and destroy any cache
data that remains in either controllers cache:
SET NOMULTIBUS_FAILOVER DESTROY_UNFLUSHABLE_DATA
See also
SET FAILOVER
SET MULTIBUS_FAILOVER
SET NOFAILOVER
Seitenansicht 403
1 2 ... 399 400 401 402 403 404 405 406 407 408 409 ... 575 576

Kommentare zu diesen Handbüchern

Keine Kommentare