Hp Array Controller HSG V8.7 Software Bedienungsanleitung Seite 204

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 576
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 203
5–8 HSG80 User’s Guide
Replacing Modules in a Dual-Redundant Controller
Configuration
Follow the instructions in this section to replace modules in a dual-
redundant controller configuration (see Figure 5–2). If you’re replacing
modules in a single controller configuration, see “Replacing Modules in
a Single Controller Configuration,” page 5–2.
Figure 5–2 Dual-Redundant Controller Configuration
The following sections cover procedures for replacing both the
controller and cache module, replacing the controller, and replacing the
cache module.
Note the following before starting the replacement procedures:
The new controller’s hardware must be compatible with the
functioning controller’s hardware. See the product-specific release
notes that accompanied the software release for information
regarding hardware compatibility.
The software versions and patch levels must be the same on both
controllers.
The new cache module must contain the same memory
configuration as the module it’s replacing.
CXO6189A
Seitenansicht 203
1 2 ... 199 200 201 202 203 204 205 206 207 208 209 ... 575 576

Kommentare zu diesen Handbüchern

Keine Kommentare