58 HSG80 Users Guide
Replacing Modules in a Dual-Redundant Controller
Configuration
Follow the instructions in this section to replace modules in a dual-
redundant controller configuration (see Figure 52). If youre replacing
modules in a single controller configuration, see Replacing Modules in
a Single Controller Configuration, page 52.
Figure 52 Dual-Redundant Controller Configuration
The following sections cover procedures for replacing both the
controller and cache module, replacing the controller, and replacing the
cache module.
Note the following before starting the replacement procedures:
The new controllers hardware must be compatible with the
functioning controllers hardware. See the product-specific release
notes that accompanied the software release for information
regarding hardware compatibility.
The software versions and patch levels must be the same on both
controllers.
The new cache module must contain the same memory
configuration as the module its replacing.
CXO6189A