Seitenansicht 182
Troubleshooting 429
Checking Unit Status and I/O Activity
Use the cache display to see the status and I/O activity for the logical
units configured on the controller (see Figure 44). Table 48 lists the
heading and contents for each column of the device status region.
Figure 44 Unit Status on the Cache Display
VTDPY> DISPLAY CACHE
S/N: ZG64100176 SW: v7.0 HW: CX-02
66% I/D Hit 99.8% Idle 0 KB/S 0 Rq/S Up: 0 5:16.42
Unit ASWC KB/S Rd% Wr% Cm% HT% PH% MS% Purge BlChd BlHit
P0300o 0 000000000
D0303o^ b 0 000000000
D0304 0 000000000
P0400 0 000000000
P0401 0 000000000
D0402x^ b 0 000000000
Table 48 Unit Status Columns
Column Contents
Unit Kind of unit (and its unit number):
D = disk drive or CD-ROM drive
P = passthrough device
? = unknown device type
A Availability of the unit:
a = available to other controller
d = disabled for servicing, offline
e = mounted for exclusive access by a user
f = media format error
i = inoperative
m = maintenance mode for diagnostic purposes
o = online. Host may access this unit through this
controller.
r = rundown with the SET NORUN command
v = no volume mounted due to lack of media