D78 HSG80 Users Guide
0B The other controller in a dual-redundant configuration has been reset with the Kill line
by the controller that reported the event.
To restart the Killed controller enter the CLI command RESTART OTHER on the
Surviving controller and then depress the (//) RESET button on the Killed controller.
If the other controller is repeatedly being Killed for the same or a similar reason, follow
repair action 20.
0C Both controllers in a dual-redundant configuration are attempting to use the same SCSI
ID (either 6 or 7 as indicated in the event report).
Note that the other controller of the dual-redundant pair has been reset with the Kill line
by the controller that reported the event. Two possible problem sources are indicated:
A controller hardware failure.
A controller backplane failure.
First, follow repair action 20 for the Killed controller. If the problem persists follow
repair action 20 for the Surviving controller. If the problem still persists replace the
controller backplane.
0D The Environmental Monitor Unit has detected an elevated temperature condition. Check
the shelf and its components for the cause of the fault.
0E The Environmental Monitor Unit has detected an external air-sense fault. Check
components outside of the shelf for the cause of the fault.
0F An environmental fault previously detected by the Environmental Monitor Unit is now
fixed. This event report is notification that the repair was successful.
10 Restore on-disk configuration information to original state.
20 Replace the controller module.
22 Replace the indicated cache module or the appropriate memory DIMMs on the indicated
cache module.
23 Replace the indicated write cache battery. CAUTION: BATTERY REPLACEMENT
MAY CAUSE INJURY.
Table D4 Recommended Repair Action Codes (Continued)