Event Reporting: Templates and Codes D–3
Last Failure Event Sense Data Response
Unrecoverable conditions detected by either software or hardware and
certain operator-initiated conditions result in the termination of HSG80
controller operation. In most cases, following such a termination, the
controller will attempt to restart (that is, reboot) with hardware
components and software data structures initialized to the states
necessary to perform normal operations (see Figure D–2).
Instance Codes (byte offset 32-35) are described in Table D–1,
“Instance Codes” on page D–18.
ASC and ASCQ codes (byte offsets 12 and 13) are described in
Table D–7, “ASC and ASCQ Codes” on page D–85.
Last Failure Codes (byte offset 104-107) are described in Table
D–3, “Last Failure Codes” on page D–38.