536 HSG80 Users Guide
In a dual-redundant configuration, FRUTIL also displays:
The configuration has two controllers.
To restart the other controller:
1. Type restart other_controller.
2. Press and hold the reset button while inserting the
program card on the slot A [or B] controller, then
release the reset button.
The controller will restart.
Field Replacement Utility terminated.
13. To allow the other controller to restart, type the following command:
RESTART OTHER _CONTROLLER
14. Hold the reset button while inserting the program card into the
controller. Release the reset button and replace the ESD cover. The
controller will restart.
15. Enable failover and re-establish the dual-redundant configuration with
the following command:
SET FAILOVER COPY=THIS_CONTROLLER
This command copies the subsystems configuration from this
controller to the other controller.
16. Disconnect the PC or terminal from the controllers maintenance port.
Replacing the PVA in the First Expansion (ID 2) or Second Expansion (ID 3)
Enclosure
Use the following steps to replace the PVA in the first expansion (ID 2)
or second expansion (ID 3) enclosure:
1. Connect a PC or terminal to the controllers maintenance port.
2. In a dual-redundant controller configuration, disable failover with the
following command:
SET NOFAILOVER
3. In a dual-redundant controller configuration, remove the program cards
ESD cover and program card from the other controller. Save them for
reinstallation.