C8 HSG80 Users Guide
Flashing OCP Patterns
Table C2 Flashing OCP Patterns
Pattern
OCP
Code
Error Repair Action
■❍❍❍❍❍
1 Program card EDC error Replace program card
■❍❍❍●❍❍
4 Timer zero on the processor is bad Replace controller
■❍❍❍●❍●
5 Timer one on the processor is bad Replace controller
■❍❍❍●●❍
6 Processor Guarded Memory Unit
(GMU) is bad
Replace controller
■❍❍●❍●●
B Nonvolatile Journal Memory (JSRAM)
structure is bad because of a memory
error or an incorrect upgrade procedure
First, verify correct upgrade (see
Release Notes). If error
continues, replace controller
■❍❍●●❍
D One or more bits in the diagnostic
registers did not match the expected
reset value
Press the reset button to restart
the controller. If this does not
correct the error, replace the
controller
■❍❍●●●❍
E Memory error in the JSRAM Replace controller
■❍❍●●●●
F Wrong image found on program card Replace program card or replace
controller if needed
■❍●❍
10 Controller Module memory is bad Replace controller
■❍●❍●❍
12 Controller Module memory addressing
is malfunctioning
Replace controller
■❍●❍●●
13 Controller Module memory parity is not
working
Replace controller
■❍●❍●❍
14 Controller Module memory controller
timer has failed
Replace controller
■❍●●❍
15 The Controller Module memory
controller interrupt handler has failed
Replace controller
■❍●●●●❍
1E During the diagnostic memory test, the
Controller Module memory controller
caused an unexpected Non-Maskable
Interrupt (NMI)
Replace controller
■●❍❍●❍
24 The cards code image changed when
the contents were copied to memory
Replace controller