Replacement Procedures 55
6. See Configuring an HSG80 Array Controller, page 23, to configure
the controller.
Note If the controller youre installing was previously used in another
subsystem, it will need to be purged of the controllers old
configuration (see CONFIGURATION RESET, page B45).
7. To restore a configuration saved with the SAVE_CONFIGURATION
switch, hold button 6 while releasing the reset button.
8. Using CLCP, install any patches that you had installed on the previous
controller (see Installing a Software Patch, page 66).
9. Mount the logical units on the host. If you are using a Windows NT
platform, restart the server.
10. Set the subsystem date and time with the following command:
SET THIS_CONTROLLER TIME=dd-mmm-yyyy:hh:mm:ss
11. Disconnect the PC or terminal from the controllers maintenance port.