Table 7–4 DS15 initialization commands with MODEMDEF enabled
Modem
Command
Description
&C1 Normal Carrier Detect (CD) operations
&Kx Select flow control per the current COM1 settings, where x is as follows:
0: No flow control
3: Hardware flow control
4: Software (XON/XOFF) flow control
6: Both hardware and software flow control
enable reboot
The enable reboot command enables the watchdog timer to reset the system if the timer
should expire. By default, the system does not reset if the watchdog timer expires (and the
watchdog timer is enabled).
NOTE: The watchdog timer is not available on DS15 systems.
enable remote
The enable remote command enables remote access to the RMC’s modem port. It also
allows the RMC to automatically dial the pager number set with the set dial command upon
the detection of an alert condition, if alerts are enabled. Before the enable remote
command can be used, the system must be configured for remote dial-in. See section 7.7.
enable thermal
The enable thermal command allows the RMC to power off the system in the event of an
over-temperature condition. By default, thermal failures powers off the system after a 3
minute lapse.
enable warning
The enable warning command allows warning-level events to generate system alerts (by
default, warnings do not generate alerts).
Note that alerts are delivered in the order in which they occur. Therefore, a pending
warning-level alert blocks the delivery of a fatal-level alert (although the fatal alerts
continue to be logged).