7.12 Troubleshooting Tips
Table 7–5 lists possible causes and suggested solutions for symptoms.
Table 7–5 RMC Troubleshooting
Symptom Possible Cause Suggested Solution
You cannot enter the
RMC from the modem.
The RMC may be in soft bypass or
firm bypass mode.
Issue the show com1_mode
command from SRM and change
the setting if necessary.
The terminal cannot
communicate with the
RMC correctly.
System and terminal baud rates do not
match.
Set the baud rate for the terminal to
be the same as for the system. For
first-time setup, note that the RMC
and system default baud is 9600.
RMC will not answer
when the modem is
called.
Modem cables may be incorrectly
installed.
Check modem phone lines and
connections.
RMC remote access is disabled or the
modem was power cycled since last
being initialized.
From the local serial terminal or
VGA monitor, enter the set
password and set init commands,
and then enter the enable remote
command. (See Section 7.7.)
The modem is not configured
correctly.
Modify the modem initialization
string according to your modem
documentation.
RMC will not answer
when modem is called.
On AC power-up, RMC defers
initializing the modem for 30 seconds
to allow the modem to complete its
internal diagnostics and initializations.
Wait 30 seconds after powering up
the system and RMC before
attempting to dial in.
7-44 hp AlphaServer/AlphaStation DS15 Service Guide