2.2.8 Memory Problems
Memory problems may affect system performance. Use the following table to
troubleshoot these problems.
Table 2–9 Memory Testing
Symptom Action
DIMMs ignored by system, or
system unstable. System hangs or
crashes.
Ensure that each memory array has identical DIMMs installed.
DIMMs failing memory power-
up self-test.
Replace the DIMMs that the SROM has isolated on power up.
See Example 2–1.
DIMMs may not have ECC bits. Some third-party DIMMs may not be compatible with DS15
systems. Ensure that the DIMMs are qualified.
Noticeable performance
degradation. The system may
appear hung or run very slowly.
This could be a result of hard single-bit ECC errors on a
particular DIMM. Check the error logs for memory errors.
Ensure that the memory DIMMs are qualified.
Example 2–1 Memory Sizing
Memory sizing in progress
Memory configuration in progress
Testing AAR2
Memory data test in progress
Memory data path error
ErrAdr: 00000000.00000000
Expect: 00000000.00000001
Actual: 00000000.00000000
XORval: 00000000.00000001
Testing AAR0
Memory data test in progress
Memory address test in progress
Memory pattern test in progress
Memory initialization
Failed DIMM 3
Loading console
Code execution complete (transfer control)
2-12 hp AlphaServer/AlphaStation DS15 Service Guide