Latest Alert: AC Loss
Init String: AT&H2E0&C1&D0S0=2
Dial String: ATD915085554444
Alert String: ,,,,,,,,,,5551234
User String:
Com1 Baud:9600 Flow:SOFTWARE Mode:THROUGH Modem:DISABLED Rmc:ENABLED
Logout Timer: 20 minutes
Voltage Status: OK
Thermal Status: OK Thermal Shutdown: Enabled
Warning Threshold: 45.00°C Fatal/Power-Down Threshold: 50.00°C
Fan Status: OK Fan Shutdown: Enabled
PCI Riser: Installed
POST DPR: OK NVRAM: OK GPIOs: OK LM75: OK
RMC>
n
Sets the password that is prompted for at the beginning of a modem session. The string
cannot exceed 14 characters and is not case sensitive. For security, the password is not echoed
on the screen. When prompted for verification, type the password again.
o
Sets the initialization string. The string is limited to 31 characters and can be modified
depending on the type of modem used. Because the modem commands disallow mixed cases,
the RMC automatically converts all alphabetic characters entered in the init string to
uppercase.
p
Clears the current alert.
q
Tells the RMC not to append its own fixed flow-control and carrier-detect commands to the
user-supplied modem initialization string. Instead, these will be included as part of the user-
supplied initialization string.
\
Enables remote access to the RMC modem port by configuring the modem with the setting
stored in the initialization string once the modem is connected to the system.
]
Status of the RMC configuration.
NOTE: Once the RMC is configured, disconnect the VT terminal from COM1 (if present)
and connect the modem.
7-22 hp AlphaServer/AlphaStation DS15 Service Guide