5.3 Machine Checks/Interrupts
The exceptions that result from hardware system errors are called machine
checks/interrupts. They occur when a system error is detected during the processing of
a data request.
During the error-handling process, errors are first handled by the appropriate PALcode error
routine and then by the associated operating system error handler. PALcode transfers
control to the operating system through the PAL handler.
Table 5–2 lists the machine checks/interrupts that are related to error events. The
designations – 630, 670, 620, 660, and 680 – indicate a system control block (SCB) offset to
the fatal system error handler for Tru64 UNIX and OpenVMS.
Table 5–2 Machine Checks/Interrupts
Error Type Error Descriptions
CPU Correctable Error (630)
Generic Alpha 21264C
(EV68) correctable errors.
B-cache probe hit single-bit ECC error
D-cache tag parity error on issue
I-cache tag or data parity error
D-cache victim single-bit ECC error
B-cache single-bit ECC fill error to I-stream or D-stream
Memory single-bit ECC fill error to I-stream or D-stream
CPU Uncorrectable Error
(670)
Fatal microprocessor
machine check errors that
result in a system crash.
PAL detected bugcheck error
Operating system detected bugcheck error
EV68 detected second D-cache store EEC error
EV68 detected D-cache tag parity error in pipeline 0 or 1
EV68 detected duplicate D-cache tag parity error
EV68 detected double-bit ECC memory fill error
EV68 detected double-bit probe hit EEC error
EV68 detected B-cache tag parity error
5-16 hp AlphaServer/AlphaStation DS15 Service Guide