Message name / descriptionASCQASCSense
key
LOGICAL UNIT TURNED ON-LINE
Through the menu options, bring the library on-line. This message is
informational only; no action is required.
09806
LOGICAL UNIT TAKEN OFFLINE
Library was taken off-line through the remote web management or OCP.
09806
DATA TRANSFER CHANGED
A drive has been inserted/removed into the system. Use “Read Element
Status” to determine status of drives.
0E806
MODE PARAMETERS CHANGED
Mode parameters may have changed due to another host issuing a Mode
Select command.
012A6
MAGAZINE INSERTED
A tape cartridge magazine has been inserted.
133B6
LOGICAL UNIT COMMUNICATION FAILURE
Check cables. Ensure library unit is powered on. Retry command.
0008B
LIBRARY COMMUNICATION TIME-OUT
Internal communications not responding. Retry command. Check the
following internal cable connections: Ethernet cable, umbilical cable,
robotics controller, cabinet controller.
0108B
INCOMPATIBLE MEDIA
An attempt was made to move media to a destination element that is
incapable of receiving it. Make sure you are using the correct media
and that it is labeled with the correct barcode.
0030B
SCSI MESSAGE ERROR
Detected message error in message processing on the SCSI BUS.
• Verify termination.
• Verify SCSI cable connections.
• Check host status.
• Restart system.
0043B
SCSI PARITY ERROR
SCSI Parity Error detected.
• Verify termination.
• Verify SCSI cable connections and cable length.
• Check host status.
• Restart the system.
0047B
INITIATOR DETECTED ERROR MESSAGE RECEIVED0048B
Sense data values136