HP StorageWorks
3Gb SAS BL Switch User Guide
The HP StorageWorks 3Gb SAS BL Switch (3Gb SAS BL Switch) is a single-wide interconnect module for HP
BladeSystem c-Class enclosures. The 3Gb SAS BL Switch is a key component of HP Direct-Connect External SAS
Storage for HP BladeSystem Solutions, with firmware and hardware capabilities that enable the connection of
external storage and tape devices to HP BladeSystem c-Class enclosures.
Part number: 516647-002
Second edition: November 2009
Seitenansicht 0
1 2 3 4 5 6 ... 55 56

Inhaltsverzeichnis

Seite 1 - 3Gb SAS BL Switch User Guide

HP StorageWorks3Gb SAS BL Switch User GuideThe HP StorageWorks 3Gb SAS BL Switch (3Gb SAS BL Switch) is a single-wide interconnect module for HPBladeS

Seite 2

Introduction10

Seite 3 - Contents

2 Component identification• Off—Normal• Solid blue—Being identified• Blinking blue—Firmware is being updatedUnit ID LED1• Off—Not powered up• Solid gr

Seite 4

Component identification12

Seite 5

3 Installation procedures3Gb SAS BL Switch installation procedures include the following steps:• Planning the configuration, page 13• Selecting the in

Seite 6

Installing the switchNOTE:• The 3Gb SAS Switch can be hot-installed in an operational BladeSystem c-Class enclosure.• Make sure that the mezzanine car

Seite 7 - 1 Introduction

3. Install the switch in the open interconnect bay.When installed in an operational enclosure, the switch automatically powers up and performs aseries

Seite 8 - Types of supported devices

Confirming the firmware versionFirmware is pre-installed on each switch in the factory, but updated, alternative, or a preferred versionmay be availab

Seite 9 - Tape devices

Cabling the switchAfter confirming the firmware version, connect SAS cables between the switch and the external SASstorage enclosures or tape devices.

Seite 10 - Introduction10

Cabling examplesExamples in this section illustrate just a few of the possible configurations using 3Gb SAS BL Switches.For a wide variety of example

Seite 11 - 2 Component identification

Shared storage—single controller, standard cablingThis example illustrates standard cabling for a single-controller controller enclosure. In this conf

Seite 12 - Component identification12

Legal and notice information© Copyright 2009 Hewlett-Packard Development Company, L.P.The information contained herein is subject to change without no

Seite 13 - 3 Installation procedures

Shared storage—dual controller, standard cablingThis example illustrates standard cabling for a high-availability configuration. In this configuration

Seite 14 - Installing the switch

Shared storage—dual controller, optimal cablingThis example illustrates optimal cabling for a high-performance, high-availability configuration. In th

Seite 15 - Accessing the switch

Zoned storage—single domain, standard cablingThis example illustrates standard cabling for a single-domain configuration using single-port SATAdisk dr

Seite 16 - Installation procedures16

Zoned storage—dual domain, standard cablingThis example illustrates standard cabling for a high-availability configuration when using dual-portSAS dis

Seite 17 - Cabling the switch

Zoned storage—dual domain, wide-port cablingThis example illustrates cabling for an optimal high-performance, high-availability configuration whenusin

Seite 18 - Cabling examples

Tape enclosure cablingThe purpose of this example is to show cabling to a tape library.IMPORTANT:The following illustration shows an MSA2012sa in the

Seite 19

Configuring the switchKey configuration tasks include:1. Enabling or disabling Multi-initiator mode.2. Creating zone groups:• Switch-port zone groups:

Seite 20

4 Supported software toolsPrimary configuration and management utilities include:• HP Onboard Administrator overview• HP Virtual SAS Manager overviewH

Seite 21

HP Virtual SAS Manager overviewHP Virtual SAS Manager (VSM) is embedded in the 3Gb SAS BL Switch firmware and is the softwareapplication used to creat

Seite 22

5 FirmwareFirmware is managed using the Virtual SAS Manager (VSM) application. For more information, seethe HP Virtual SAS Manager user guide, availab

Seite 23

Contents1 Introduction ... 7Features ...

Seite 24

Firmware30

Seite 25 - Tape enclosure cabling

6 TroubleshootingSolutionProblem• Check OA and VSM for status alerts to identify the problem.• See Chapter 2 on page 11 for LED definitions.Amber LED

Seite 27 - 4 Supported software tools

7 Internal mappings and cablingrecommendationsWhen attaching storage enclosures to SAS ports on the HP 3G SAS BL Switch, use the followingcabling guid

Seite 28 - Supported software tools28

c7000 recommendationsTable 4 Half-height server blades in c7000 device bays 1–8• Install 3Gb SAS BL Switches in c7000 interconnect bays 3 and4• Attach

Seite 29 - 5 Firmware

nlnlTable 8 Full-height server blades in c7000 device bays• Install 3Gb SAS BL Switches in c7000 interconnect bays 3 and4• Attach storage enclosures f

Seite 30 - Firmware30

Internal mappings and cabling recommendations36

Seite 31 - 6 Troubleshooting

8 Technical specificationsGeneral specificationsMPC8343a running at 400MHzCommunicationsnlprocessor3 Gb SAS x2To server blades:Data path 3 Gb SAS x4To

Seite 32 - Troubleshooting32

Technical specifications38

Seite 33

9 Electrostatic dischargePreventing electrostatic dischargeTo prevent damaging the system, be aware of the precautions you need to follow when setting

Seite 34

Power and environmental specifications ... 379 Electrostatic disch

Seite 35

Electrostatic discharge40

Seite 36

10 Support and other resourcesContacting HPBefore you contact HPBe sure to have the following information available before you call or contact HP:• Te

Seite 37 - 8 Technical specifications

Documentation feedbackHP welcomes your feedback.To make comments and suggestions about product documentation, please send a message tostoragedocsFeedb

Seite 38 - Technical specifications38

Document conventions and symbolsElementConventionCross-reference links and e-mail addressesBlue text: Document conventions and symbolsWebsite addresse

Seite 39 - 9 Electrostatic discharge

Customer self repairHP customer self repair (CSR) programs allow you to repair your StorageWorks product. If a CSRpart needs replacing, HP ships the p

Seite 40 - Electrostatic discharge40

11 Regulatory compliance noticesThis section contains regulatory notices for the HP StorageWorks 3Gb SAS BL Switch.Regulatory compliance identificatio

Seite 41 - Contacting HP

radiate radio frequency energy and, if not installed and used in accordance with the instructions,may cause harmful interference to radio communicatio

Seite 42 - Related information

Class B equipmentThis Class B digital apparatus meets all requirements of the Canadian Interference-Causing EquipmentRegulations.Cet appareil numériqu

Seite 43

Japanese noticesKorean noticesClass A equipmentClass B equipmentRegulatory compliance notices48

Seite 44 - Rack stability

BSMI Class A noticeChinese noticeRecycling noticesEnglish noticeBulgarian notice3Gb SAS BL Switch User Guide 49

Seite 45 - FCC rating label

Polish notice ... 53Portuguese noti

Seite 46 - Class A equipment

Czech noticeDanish noticeDutch noticeEstonian noticeRegulatory compliance notices50

Seite 47 - Class B equipment

Finnish noticeFrench noticeGerman noticeGreek notice3Gb SAS BL Switch User Guide 51

Seite 48 - Korean notices

Hungarian noticeItalian noticeLatvian noticeLithuanian noticeRegulatory compliance notices52

Seite 49 - Recycling notices

Polish noticePortuguese noticeRomanian noticeSlovak notice3Gb SAS BL Switch User Guide 53

Seite 50 - Estonian notice

Spanish noticeSwedish noticeTurkish noticeTürkiye Cumhuriyeti: EEE Yönetmeli ine UygundurRegulatory compliance notices54

Seite 51 - Greek notice

IndexAaccessing the switch, 15Bbest practicescabling, 17zoned cabling, 17Ccablingbest practices, 17examples of, 18procedures, 17shared storage, dual c

Seite 52 - Lithuanian notice

JJapanese notices, 48KKorean notices, 48LLED definitions, 11Mmanagement tools, 27managing firmware, 29mappings, 13table of,OOnboard Administrator (OA)

Seite 53 - Slovak notice

TablesHalf-height server blades in c3000 device bays ... 331BL2x220c server blades in c3000 dev

Seite 54 - Turkish notice

1 IntroductionThe HP StorageWorks 3Gb SAS BL Switch (3Gb SAS BL Switch) is a single-wide interconnect modulefor HP BladeSystem c-Class enclosures that

Seite 55

Types of supported devicesThe 3Gb SAS BL Switch supports the following types of devices:• Shared storage enclosures, page 8• Zoned storage enclosures,

Seite 56

• Server bays that need access to external storage must be assigned the appropriate zone group.• A server bay can be assigned multiple zone groups.• A