HP StorageWorks Virtualization ServicesManager v2 server user guideThis guide provides basic information about the Virtualization Services Manager (VS
Rear panel LEDs and buttonsTable 4 Rear panel LEDs and buttonsStatusDescriptionItemGreen = Activity exists.Flashing green = Activity exists.Off = No a
StatusDescriptionItemGreen = NormalOff = One or more of the following conditions exists:• AC power unavailable• Power supply failed• Power supply in s
Table 6 HP Systems Insight Display LEDsStatusDescriptionItemTo determine Power cap status, see “System Insight Display LEDcombinations” on page 13.Pow
System Insight Display LED combinationsWhen the health LED on the front panel illuminates either amber or red, the server is experiencing ahealth even
StatusSystem power LEDHealth LEDSystems Insight DisplayLED and colorStandbyAmber—Power cap (off)Waiting for powerFlashing green—Power cap (green)Power
SAS hard drive LEDsTable 8 SAS hard drive LEDsDescriptionItemFault/UID LED (amber/blue)1Online LED (green)2SAS hard drive LED combinationsTable 9 SAS
InterpretationFault/UID LED(amber/blue)Online/activityLED (green)CAUTION:Do not remove the drive. Removing a drive may terminatethe current operation
2 OperationsPower up the serverTo power up the server, press the Power On/Standby button.Power down the serverWARNING!To reduce the risk of personal i
1. Power down the server (see page 17).2. Disconnect all peripheral cables and power cords.3. Loosen the front panel thumbscrews.4. Extend the server
2. Extend the display from the chassis.The display can be rotated up to 90 degrees.HP StorageWorks Virtualization Services Manager v2 server user guid
Legal and notice information© Copyright 2009 Hewlett-Packard Development Company, L.P.The information contained herein is subject to change without no
Operations20
3 SetupRack planning resourcesThe rack resource kit ships with all HP branded or Compaq branded 9000, 10000, and H9 seriesracks. For more information
The 9000 and 10000 Series Racks provide proper server cooling from flow-through perforations inthe front and rear doors that provide 64 percent open a
WARNING!To reduce the risk of personal injury, fire, or damage to the equipment, do not overload the AC supplybranch circuit that provides power to th
Rack warningsWARNING!To reduce the risk of personal injury or damage to the equipment, be sure that:• The leveling jacks are extended to the floor.• T
WARNING!This server is very heavy. To reduce the risk of personal injury or damage to the equipment:• Observe local occupational health and safety req
To configure these utilities manually:• Press the F8 key when prompted during the array controller initialization to configure the arraycontroller usi
4 Software and configuration utilitiesConfiguration toolsSmartStart softwareSmartStart is a collection of software that optimizes single-server setup,
Default configuration settings are sufficient for proper typical server operation, but configurationsettings can be modified using RBSU. The system wi
• Online Spare Mode—Provides protection against failing or degraded DIMMs. Certain memoryis set aside as spare, and automatic failover to spare memory
Contents1 Component identification ... 7Front panel components ...
The utility also provides support for the following functions:• Reconfiguring one or more logical drives• Viewing the current logical drive configurat
System Management driver, also known as the Health Driver, is loaded. When the operating systemis functioning properly, the system periodically resets
HP Systems Insight ManagerHP SIM is a web-based application that allows system administrators to accomplish normaladministrative tasks from any remote
The Vulnerability and Patch Management Pack is an all-in-one vulnerability assessment and patchmanagement tool. It enables you to gain the upper hand
Using an integrated, wizard-based installer, Insight Control Environment suites install and configureHP Systems Insight Manager (HP SIM) and HP ProLia
• DOS• Environments which do not support USB nativelyFor additional security, external USB functionality can be disabled through RBSU.For more informa
Remote support and analysis toolsHP Insight Remote Support softwareHP Insight Remote Support software delivers secure remote support for your HP Serve
can be downloaded free of charge from the SmartStart download page on the HP website (http://www.hp.com/go/support).System Online ROM Flash Component
Software and configuration utilities38
5 TroubleshootingTroubleshooting resourcesRefer hardware and software issues with your Virtualization Services Manager server to HP Services.An additi
Management tools ... 30Automatic Serv
Important safety informationBefore servicing this product, read the Important Safety Information document provided with the server.Symbols on equipme
Warnings and cautionsWARNING!Only authorized technicians trained by HP should attempt to repair this equipment. All troubleshootingand repair procedur
CAUTION:To properly ventilate the system, you must provide at least 7.6 cm (3.0 in) of clearance at the frontand back of the server.CAUTION:The server
6. Collect all tools and utilities, such as a Torx screwdriver, loopback adapters, ESD wrist strap,and software utilities, necessary to troubleshoot t
Start diagnosis flowchartUse the following flowchart to start the diagnostic process.Refer toItem"Power-on problems flowchart (see 44)"1&quo
Possible causes:• Improperly seated or faulty power supply• Loose or faulty power cord• Power source problem• Power on circuit problem• Improperly sea
POST problems flowchartSymptoms:• Server does not complete POSTNOTE:The server has completed POST when the system attempts to access the boot device.•
Possible problems:• Improperly seated or faulty internal component• Faulty KVM device• Faulty video deviceRefer toItem"POST error messages and be
Server fault indications flowchartSymptoms:• Server boots, but a fault event is reported by Insight Management Agents (see page 32)• Server boots, but
Possible causes:• Improperly seated or faulty internal or external component• Unsupported component installed• Redundancy failure• System overtemperat
A Regulatory compliance notices ... 55Regulatory compliance identification numbers ...
POST error messages and beep codesFor a complete listing of error messages, refer to the "POST error messages" in the HP ProLiant ServersTro
6 Support and other resourcesHP technical supportFor worldwide technical support information, see the HP support website:http://www.hp.com/supportBefo
Document conventions and symbolsTable 10 Document conventionsElementConventionCross-reference links and e-mail addressesBlue text: Table 10Website add
Customer self repairThis product has no customer-replaceable components.Subscription serviceHP recommends that you register your product at the Subscr
Support and other resources54
A Regulatory compliance noticesRegulatory compliance identification numbersFor the purpose of regulatory compliance certifications and identification,
interference will not occur in a particular installation. If this equipment does cause harmful interferenceto radio or television reception, which can
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matérielbrouilleur du Canada.Class B equipmentThis Class B dig
Japanese noticeBSMI noticeKorean noticeClass A equipmentClass B equipmentRegulatory compliance notices58
Chinese noticeLaser complianceThis product may be provided with an optical storage device (that is, CD or DVD drive) and/or fiberoptic transceiver. Ea
TablesFront panel components ... 71Front panel LEDs and butt
For more information about battery replacement or proper disposal, contact an authorized reselleror an authorized service provider.Taiwan battery recy
B Electrostatic dischargePreventing electrostatic dischargeTo prevent damaging the system, be aware of the precautions you need to follow when setting
Electrostatic discharge62
C SpecificationsEnvironmental specificationsValueSpecificationTemperature range*10°C to 35°C (50°F to 95°F)Operating-40°C to 70°C (-40°F to 158°F)Ship
ValueSpecificationHP 72GB 15k SAS 2.5 HP DP HDDDisk drives (2)HP FC1242Sr 4Gb PCI-E DCHost bus adapters (2)12.7 mm SATA DVD kitDVDPower supply specifi
• x1 or x4 lane link interface (auto negotiated with system) at 2.5 Gb/s• Support for VC0 (1 Virtual Channel) and TC0 (1 Traffic Class)• Configuration
Specifications66
D Acronyms and abbreviationsabnormal endABENDArray Diagnostics UtilityADUAdvanced Memory ProtectionAMPAutomatic Server RecoveryASRbattery-backed write
ROM-Based Setup UtilityRBSURegistered Dual In-line Memory ModuleRDIMMRapid Deployment PackRDPRemote Insight Lights-Out EditionRILOEserial attached SCS
IndexAACU (Array Configuration Utility, 29ADU (Array Diagnostics Utility), 35Advanced ECC memory, 28airflow requirements, 21, 22Altiris eXpress Deploy
1 Component identificationFront panel componentsTable 1 Front panel componentsDescriptionItemHard drive bay 5 (not used)1Hard drive bay 6 (not used)2D
front panel LEDs, 8Ggrounding methods, 61grounding requirements, 23Hhard drive bays, 7hard drive LEDs, 15hard drives, 7, 14, 15hard drives, determinin
problem diagnosis, 39products, providing feedback, 53ProLiant Support Pack (PSP), 36Rrackinstallation, 24mounting hardware, 24planning resources, 21st
Wwarnings, 24, 41websitesHP, 53HP Subscriber's Choice for Business, 53product manuals, 5172
Front panel LEDs and buttonsTable 2 Front panel LEDs and buttonsStatusDescriptionItemBlue = Identification is activated.Flashing blue = System is bein
Rear panel componentsTable 3 Rear panel componentsDescriptionItemHP FC1242SR 4Gb PCI-e DC HBA 11HP FC1242SR 4Gb PCI-e DC HBA 22Power supply 1 (750 W)3
Kommentare zu diesen Handbüchern