Message name / descriptionASCQASCSense
key
DEPTH INVALID START CONDITION
Depth hardware condition is unknown. Run the Robotics to Home Position
test from the OCP.
F0875
DEPTH INVALID COMMAND
Depth hardware commanded to position out of system mechanical limits.
Run the Robotics to Home Position test from the OCP.
If the problem persists, calibrate the library.
Verify that the host software application is supported, has up-to-date
patches, and is correctly configured.
Verify that the library and its components have the current firmware.
F0875
PARAMETER LIST LENGTH ERROR
Invalid parameter list length field specified by command.
Verify that the host software application is supported, has up-to-date
patches, and is correctly configured.
Verify that the library and its components have the current firmware.
001A5
COMMAND SEQUENCE ERROR (read of unwritten echo buffer)002C5
MEDIUM NOT PRESENT
The inventory indicated that a cartridge was in this bin but no cartridge
was sensed by the picker when it attempted to pick it. It may also indicate
that the tape is not ready to be picked from the drive because the tape
is not fully unloaded.
Retry the command.
Check for proper seating of the cartridge.
003A5
MEDIUM DESTINATION ELEMENT FULL
Destination element address already contains a cartridge.
Re-inventory the cabinet and retry the move command using your
application software.
If the problem recurs, run the Robotics to Home Position test followed
by a cabinet inventory, and retry the move command using your ap-
plication software.
0D3B5
MEDIUM SOURCE ELEMENT EMPTY
Source element address does not contain a cartridge.
Re-inventory the cabinet and retry move command using your applic-
ation software.
If the problem recurs, run the Robotics to Home Position test followed
by a cabinet inventory, and retry the move command using your ap-
plication software.
0E3B5