6. Command Reference
423
started are reset to 0. Intermittent error monitoring will then resume with the
changed settings.
If you set the automatic failback function to
off while intermittent error
monitoring is
on, intermittent error monitoring will be disabled. Note, however,
that if you use the
view -sys operation to display the HDLM functionality
configuration,
Intermittent Error Monitor will be shown as on. When the
automatic failback function is returned to
on, intermittent error monitoring will
once again be enabled.
The executable operations for the automatic failback function and intermittent
error monitoring depend on the settings for those functions.
Table 6-5: Relationship Between the Setting for the Automatic Failback
Function and Intermittent Error Monitoring and the Executable Operations
shows the relationship between the settings for the automatic failback function
and intermittent error monitoring and the executable operations for those
functions.
Table 6-5: Relationship Between the Setting for the Automatic Failback
Function and Intermittent Error Monitoring and the Executable Operations
Setting Available operation Result of operation
AFB IEM
on on Set AFB to on. The operations of AFB and IEM do not change.
Change the AFB setting.
AFB is performed under the new settings.
#1
Set AFB to off. AFB and IEM are disabled.
The error count, elapsed monitoring time, and
information about paths not subject to automatic
failback are cleared.
Set IEM to
on. When a path is being monitored (during a period
of conditional intermittent error monitoring), the
value of the error count and the elapsed
monitoring time are reset to
0, and then
intermittent error monitoring will restart.
When a path is not being monitored, nothing
changes.
Change the IEM settings. While a path is being monitored, the value of the
error count and the elapsed monitoring time are
reset to 0, and then intermittent error monitoring
will restart.
#1
When a path is not being monitored, the IEM
settings will take effect again when the path is
recovered from the error status by performing an
automatic failback.