followed by a service restart. HP P6000 Performance Data Collector data collection service
restart does not cause loss of the configured HP P6000 Command View access information.
Displaying HP P6000 Command View access credentials
The EVAperf verifycvconfig command verifies whether HP P6000 Command View is
accessible using the specified access credentials. The following is a sample output:
Host Port Username Accessible
localhost 2374 adm No
Configuration file for performance and state data logging
The logging.conf file is located in the HP P6000 Performance Data Collector install directory.
This file contains the parameters that control the logging. The format of the file is as follows:
#state_logging parameter controls the tracking and logging of state changes
#if this is set to yes, the performance data logging also needs to be enabled
state_logging no
#perf_logging parameter controls the logging of performance metrics
perf_logging no
#Frequency at which state data needs to be polled and logged (time is in
minutes)
state_interval 60
#Frequency at which performance data needs to be polled and logged (time is
in seconds)
perf_interval 300
#Directory under which state and performance data will be logged (use /
instead of \ to separate directories)
#for example c:/all_logs/eva_logs
#default log directory is performance_history under the current directory
root /performance_history
#Max size of a log file in MB
filesize 50
#Number of days for which the logs need to be retained
numdays 3
The logging parameters are as follows:
Minimum value for perf polling interval is 30 seconds and maximum is 24 hours.
Minimum value for state polling interval is 30 minutes and maximum is 24 hours.
Minimum value for logfilesize is 1 MB.
By default, a directory with the name performance_history is created in the install
directory, where all the state and performance data is logged. If this is changed, you must
ensure that the directory specified as the root directory for logging exists. Otherwise, state
and performance data will not be logged.
Minimum number of days for which logs must be retained is 1. Specifying any value other
than yes for perf_logging and state_logging parameters results in logging being turned off.
Configuring HP P6000 Performance Data Collector
To begin storage system monitoring, ensure that HP P6000 Performance Data Collector is configured
properly.
78 Monitoring array performance using HP P6000 Performance Data Collector