Hp ProLiant DL380 G5 Server Bedienungsanleitung Seite 53

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 98
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 52
Fan Status—Displays the status of the fan subsystem in the drive enclosure, or box. The following values are
possible:
OK—The fan subsystem is working properly.
Failed—A fan has failed and there are not enough fans in the fan subsystem to keep the enclosure cool. Check
your fan subsystem as soon as possible. Continued operation may cause failure of the drives.
Degraded—A fan has failed but there are still enough fans in the fan subsystem to keep the enclosure cool.
Unknown—The Storage Agents do not recognize the status of the fan subsystem. You may need to upgrade
your software.
No Fan—This storage system does not have a fan.
Backplane Speed—Displays the speed of the storage system backplane. The following values are possible:
Ultra3—The storage system is capable of Ultra3 speeds.
Ultra320—The storage system is capable of Ultra320 speeds.
Unknown—The Storage Agents are unable to determine the storage system backplane speed. You may
need to upgrade your software.
Connection Type—Displays the type of connection between the server and the box. The following values are
possible:
Fibre Attached—This chassis is attached to the server through Fibre Channel.
SCSI Attached—This chassis is attached to the server with a SCSI cable.
SAS Attached—This chassis is attached to the server with a SAS cable.
Unknown—The Storage Agents are unable to determine the type of connection.
Drive Bays—Displays the number of drive bays provided by this storage system. If duplexing hardware is used
with the storage system, the drive bay number is less than the number of physical drive bays in the enclosure.
Model—isplays the model of the storage system. Use this information for identification purposes.
Board Revision—Displays the board revision level of this storage system backplane.
Thermal Status—Displays the temperature status of the drive system. The following values are possible:
OK—The temperature is within normal operating range.
Degraded—The temperature is outside of normal operating range. Check to make sure the cover is on the
storage system.
Failed—The temperature is outside of normal operating range, and could permanently damage the system.
Ensure that the fans are spinning, and check the room temperature.
Unknown—The Storage Agents do not recognize the thermal status. You may need to upgrade your
software.
No Temperature Monitoring—This storage system does not support temperature monitoring.
Side Panel—Displays the status of the side panel of the drive enclosure, or box. The following values are
possible:
In Place—The side panel is closed.
Removed—The side panel is not in place or not completely closed.
Unknown—The Storage Agents do not recognize the side panel status. You may need to upgrade your
software.
No Panel Detection—This storage system does not support side panel detection.
Duplex Option—Displays the duplex option installed in this storage system. The following values are possible:
Duplex Top—This storage system is the top part of a duplexed unit.
Duplex Bottom—This storage system is the bottom part of a duplexed unit.
None—A duplex option is not installed.
Power Supply Status—Displays the status of the redundant power supply. The following values are possible:
OK—All component power supplies that make up the redundant power supply are in normal working order.
Degraded—One of the component power supplies that make up the redundant power supply has failed.
The drive system (either a drive subsystem or a power supply for the main unit) continues to operate;
however, if the remaining power supply should fail, the drive system loses power and data loss could occur.
To correct this situation, schedule a time to bring the device down and replace the failed power supply.
Unknown—The Storage Agents do not recognize the redundant power supply. You may need to upgrade
your software.
No Redundant Power Supply—This ProLiant server does not support a redundant power supply.
Paths—Displays the status and role of each data path to
the storage system (for multipath capable hardware
only). The following values are possible:
Agent information 53
Seitenansicht 52
1 2 ... 48 49 50 51 52 53 54 55 56 57 58 ... 97 98

Kommentare zu diesen Handbüchern

Keine Kommentare