Hp ProLiant ML310 G5p Server Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Computerhardware Hp ProLiant ML310 G5p Server herunter. HP ProLiant ML310 G5p Server User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 103
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
HP ProLiant ML310 Generation 5p Server
User Guide
Abstract
This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the
servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels.
Part Number: 515104-003
October 2012
Edition: 3
Seitenansicht 0
1 2 3 4 5 6 ... 102 103

Inhaltsverzeichnis

Seite 1 - User Guide

HP ProLiant ML310 Generation 5p Server User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and

Seite 2

Component identification 10 Rear panel LEDs • Redundant hot-plug power supply model Item LED Status 1 NIC/iLO 2 link On = Link Off = No lin

Seite 3 - Contents

Index 100 A access panel 18, 19 ACU (Array Configuration Utility) 52 adapter LEDs 7, 10 additional information 63 air baffle 20 airflow re

Seite 4 - Contents 4

Index 101 environmental specifications 88 Erase Utility 57 error messages 78 European Union notice 83 expansion boards 38, 39 expansion sl

Seite 5 - Contents 5

Index 102 LEDs, troubleshooting 8, 13, 14, 63 loose connections 66 M Management Agents 58 management tools 56 media bay blank 6, 19 memory

Seite 6 - Component identification

Index 103 server fault indications flowchart 76 server features and options 28 server options, installing 25, 28 server setup 25 server spec

Seite 7 - Front panel LEDs and buttons

Component identification 11 Item LED Status 1 NIC/iLO 2 link On = Link Off = No link 2 NIC/iLO 2 activity Flashing = Activity Off = No activi

Seite 8 - SAS and SATA device numbers

Component identification 12 Item Description 19 PCI fan connector 20 System battery 21 SATA connector 4 (hard drive) 22 SATA connector 6 (optical d

Seite 9 - Rear panel components

Component identification 13 NMI functionality An NMI crash dump enables administrators to create crash dump files when a system is hung and not resp

Seite 10 - Rear panel LEDs

Component identification 14 Item LED description Status 8 DIMM 4 failure Amber = DIMM has failed or is missing. Off = Normal 9 DIMM 3 failure Am

Seite 11 - System board components

Component identification 15 PCI-X extender board components Item Description 1 PCI-X expansion slot 1 2 System board connector Fan locations

Seite 12 - System maintenance switch

Operations 16 Operations Power up the server To power up the server, press the Power On/Standby button. Press the F9 key, when prompted during the b

Seite 13 - System board LEDs

Operations 17 Unlock the bezel Unlock and remove the bezel before accessing the hard drive cage and media bays. Unlock the bezel before removing the

Seite 14

Operations 18 3. Remove the bezel. Remove the access panel WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives

Seite 15 - Fan locations

Operations 19 4. Power up the server (on page 16). Remove a media bay blank 1. Power down the server (on page 16). 2. Remove the front bezel (&qu

Seite 16 - Operations

© Copyright 2011, 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warr

Seite 17 - Remove the bezel

Operations 20 Remove the system air baffle and PCI card guide WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives

Seite 18 - Install the access panel

Setup 21 Setup Optional installation services Delivered by experienced, certified engineers, HP Care Pack services help you keep your servers up and

Seite 19 - Remove a bezel blank

Setup 22 Space and airflow requirements To allow for servicing and adequate airflow, observe the following space and airflow requirements when decid

Seite 20

Setup 23 Power requirements Installation of this equipment must comply with local and regional electrical regulations governing the installation of

Seite 21 - Optimum environment

Setup 24 WARNING: To reduce the risk of personal injury or damage to the equipment, be sure that: • The leveling jacks are extended to the floor.

Seite 22 - Temperature requirements

Setup 25 Identifying server shipping carton contents Unpack the server shipping carton and locate the materials and documentation necessary for inst

Seite 23 - Warnings and cautions

Setup 26 The server might look different than shown. Item Description 1 Power supply connector 2 Mouse connector 3 Keyboard connector 4 10/100/

Seite 24 - Setup 24

Setup 27 • Manual installation—Insert the operating system CD into the CD-ROM drive and reboot the server. This process may require you to obtain a

Seite 25 - Setting up a server

Hardware options installation 28 Hardware options installation Introduction If more than one option is being installed, read the installation instru

Seite 26

Hardware options installation 29 Slot 1A Slot 2B Slot 3A Slot 4B Total memory Mode 2 GB — 2 GB — 4 GB Single-bank interleaved 2 GB 2 GB 2

Seite 27 - Registering the server

Contents 3 Contents Component identification ...

Seite 28 - Introduction

Hardware options installation 30 CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populate

Seite 29 - Hard drives

Hardware options installation 31 4. Install the hard drive. 5. Determine the status of the drive from the hot-plug SAS hard drive LED combinations

Seite 30

Hardware options installation 32 5. Install the optical drive. 6. Connect the power cable to the rear of the drive. 7. Connect the optical drive

Seite 31 - SATA optical drive

Hardware options installation 33 CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated

Seite 32 - USB tape drive

Hardware options installation 34 10. Power up the server (on page 16). Full-height tape drive For clarity, the following illustrations include opti

Seite 33

Hardware options installation 35 c. Close the upper and lower wire retainers. 7. Install the retaining screw. IMPORTANT: When installing a SC

Seite 34 - Full-height tape drive

Hardware options installation 36 10. Connect the data cable to the rear of the drive and to the SCSI controller. 11. Remove the applicable bezel b

Seite 35

Hardware options installation 37 5. Install the diskette drive. 6. Connect the power cable to the rear of the drive. 7. Connect the diskette driv

Seite 36 - Diskette drives

Hardware options installation 38 Installing a USB diskette drive Connect a USB diskette drive to the USB connector on the server front panel. Expa

Seite 37

Hardware options installation 39 4. Remove the expansion slot cover. CAUTION: To prevent improper cooling and thermal damage, do not operate th

Seite 38 - Expansion boards

Contents 4 SATA optical drive ...

Seite 39 - Installing expansion boards

Hardware options installation 40 6. Close the PCI retainer. 7. Connect any required internal or external cables to the expansion board. See the doc

Seite 40 - PCI-X extender board

Hardware options installation 41 6. Install the PCI fan. 7. Install the system air baffle and PCI card guide. 8. Connect the PCI fan cable to the

Seite 41 - SAS controller

Hardware options installation 42 1. Power down the server (on page 16). 2. Unlock the bezel (on page 17). 3. Remove the access panel (on page 18).

Seite 42

Hardware options installation 43 IMPORTANT: The battery pack might have a low charge when installed. In this case, a POST error message is display

Seite 43

Hardware options installation 44 7. Connect the cable to the cache module. 8. Install the battery pack. 9. Route the cable. 10. Install the acc

Seite 44

Hardware options installation 45 3. Enabling the Trusted Platform Module (on page 47). Enabling the TPM requires accessing RBSU ("HP ROM-Based

Seite 45

Hardware options installation 46 4. Install the TPM board. Press down on the connector to seat the board ("System board components" on pag

Seite 46

Hardware options installation 47 • Always store copies of the recovery key/password away from the server. • Do not save the recovery key/password

Seite 47

Cabling 48 Cabling Server cabling Item Description 1 SATA hard drive cable (hard drive) 2 Front USB cable 3 SATA optical drive cable 4 Front pa

Seite 48 - Cabling

Cabling 49 SATA hard drive cabling Item Description 1 Power cable 2 SATA cable SAS hard drive cabling Item Description 1 Power cable 2 S

Seite 49 - SAS hard drive cabling

Contents 5 Troubleshooting resources ...

Seite 50 - Configuration tools

Software and configuration utilities 50 Software and configuration utilities Configuration tools SmartStart software SmartStart is a collection of s

Seite 51 - HP ROM-Based Setup Utility

Software and configuration utilities 51 refer to the SmartStart Scripting Toolkit User Guide on the HP website (http://h18004.www1.hp.com/products/s

Seite 52 - Array Configuration Utility

Software and configuration utilities 52 NOTE: If the boot drive is not empty or has been written to in the past, ORCA does not automatically conf

Seite 53 - Embedded SATA RAID

Software and configuration utilities 53 • Remains available any time that the server is on • Displays on-screen tips for individual steps of a con

Seite 54

Software and configuration utilities 54 Legacy USB support provides USB functionality in environments where USB support is not available normally. S

Seite 55

Software and configuration utilities 55 Installing an operating system (Embedded SATA RAID) Embedded SATA RAID is only supported with the following

Seite 56 - Management tools

Software and configuration utilities 56 HP Insight Control server deployment (formerly RDP) HP Insight Control is essential server management that u

Seite 57 - Erase Utility

Software and configuration utilities 57 ASR increases server availability by restarting the server within a specified time after a system hang. At t

Seite 58 - USB support

Software and configuration utilities 58 Management Agents Management Agents provide the information to enable fault, performance, and configuration

Seite 59 - Diagnostic tools

Software and configuration utilities 59 ROM legacy USB support When using operating systems that support USB, the server supports USB devices, inclu

Seite 60 - ROMPaq disaster recovery

Component identification 6 Component identification Front panel components Item Description 1 DVD-ROM drive 2 Media bays (bezel blanks) 3 USB co

Seite 61 - Keeping the system current

Software and configuration utilities 60 HP Insight Diagnostics Online Edition is a web-based application that captures system configuration and othe

Seite 62 - Care Pack

Software and configuration utilities 61 a. The server generates one long beep and two short beeps to indicate that you are in disaster recovery mode

Seite 63 - Troubleshooting

Software and configuration utilities 62 HP SUM enables system administrators to upgrade ROM images efficiently across a wide range of servers and op

Seite 64 - Symbols on equipment

Troubleshooting 63 Troubleshooting Troubleshooting resources The HP ProLiant Servers Troubleshooting Guide provides procedures for resolving common

Seite 65 - Symptom information

Troubleshooting 64 Symbols on equipment The following symbols may be placed on equipment to indicate the presence of potentially hazardous condition

Seite 66 - Loose connections

Troubleshooting 65 WARNING: To reduce the risk of electric shock or damage to the equipment: • Do not disable the power cord grounding plug. The

Seite 67 - Troubleshooting flowcharts

Troubleshooting 66 2. Record any error messages displayed by the system. 3. Remove all diskettes, CD-ROMs, DVD-ROMs, and USB drive keys. 4. Power

Seite 68 - General diagnosis flowchart

Troubleshooting 67 Service notifications To view the latest service notifications, refer to the HP website (http://www.hp.com/go/bizsupport). Select

Seite 69

Troubleshooting 68 General diagnosis flowchart The General diagnosis flowchart provides a generic approach to troubleshooting. If you are unsure o

Seite 70 - Symptoms:

Troubleshooting 69 Item See 5 "General memory problems are occurring" in the HP ProLiant Servers Troubleshooting Guide located on the Doc

Seite 71

Component identification 7 Front panel LEDs and buttons Item Description Status 1 DVD-ROM drive ejector button — 2 DVD-ROM drive activity LED

Seite 72 - Troubleshooting 72

Troubleshooting 70 Server power-on problems flowchart Symptoms: • The server does not power on. • The system power LED is off or amber.

Seite 73 - POST problems flowchart

Troubleshooting 71 • The external health LED is red or amber. • The internal health LED is red or amber. NOTE: For the location of server LED

Seite 74

Troubleshooting 72

Seite 75 - OS boot problems flowchart

Troubleshooting 73 POST problems flowchart Symptoms: • Server does not complete POST NOTE: The server has completed POST when the system att

Seite 76 - Troubleshooting 76

Troubleshooting 74 Item See 13 • "Server information you need" in the HP ProLiant Servers Troubleshooting Guide located on the Documenta

Seite 77 - • Redundancy failure

Troubleshooting 75 OS boot problems flowchart Symptoms: • Server does not boot a previously installed operating system • Server does not boot Smar

Seite 78 - (http://www.hp.com/support)

Troubleshooting 76 Server fault indications flowchart Symptoms: • Server boots, but a fault event is reported by Insight Management Agents (on pa

Seite 79 - Troubleshooting 79

Troubleshooting 77 Possible causes: • Improperly seated or faulty internal or external component • Unsupported component installed • Redundancy f

Seite 80 - Battery replacement

Troubleshooting 78 POST error messages and beep codes For a complete listing of error messages, refer to the "POST error messages" in th

Seite 81 - FCC rating label

Troubleshooting 79 WARNING: To avoid potential problems, ALWAYS read the warnings and cautionary information in the server documentation before re

Seite 82 - Modifications

Component identification 8 SAS and SATA device numbers Hot-plug SATA or SAS hard drive LEDs Item LED description Status 1 Fault/UID status

Seite 83 - • EMC Directive 2004/108/EC

Battery replacement 80 Battery replacement If the server no longer automatically displays the correct date and time, you may need to replace the bat

Seite 84 - Korean notice

Regulatory compliance notices 81 Regulatory compliance notices Regulatory compliance identification numbers For the purpose of regulatory compliance

Seite 85 - Battery replacement notice

Regulatory compliance notices 82 radio communications. However, there is no guarantee that interference will not occur in a particular installation.

Seite 86

Regulatory compliance notices 83 This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. C

Seite 87 - Electrostatic discharge

Regulatory compliance notices 84 This symbol on the product or on its packaging indicates that this product must not be disposed of with your other

Seite 88 - Specifications

Regulatory compliance notices 85 Class B equipment Chinese notice Class A equipment Laser compliance This product may be provided with an optica

Seite 89 - Specification Value

Regulatory compliance notices 86 For more information about battery replacement or proper disposal, contact an authorized reseller or an authorized

Seite 90 - Support and other resources

Electrostatic discharge 87 Electrostatic discharge Preventing electrostatic discharge To prevent damaging the system, be aware of the precautions yo

Seite 91

Specifications 88 Specifications Environmental specifications Specification Value Temperature range* Operating 10°C to 35°C (50°F to 95°F) Sh

Seite 92 - Customer Self Repair

Specifications 89 Specification Value Maximum peak power 410 W (non-redundant non-hot-plug) 430 W (redundant hot-plug) * 100 to 127 VAC is require

Seite 93

Component identification 9 The online/activity status LED will not illuminate if using SATA drives connected to the embedded storage device. In this

Seite 94 - Reparo feito pelo cliente

Support and other resources 90 Support and other resources Before you contact HP Be sure to have the following information available before you call

Seite 95

Support and other resources 91 providers or service partners) identifies that the repair can be accomplished by the use of a CSR part, HP will ship

Seite 96

Support and other resources 92 Pour plus d'informations sur le programme CSR de HP, contactez votre Mainteneur Agrée local. Pour plus d'in

Seite 97

Support and other resources 93 HINWEIS: Einige Teile sind nicht für Customer Self Repair ausgelegt. Um den Garantieanspruch des Kunden zu erfüllen,

Seite 98 - Acronyms and abbreviations

Support and other resources 94 sustituciones que lleve a cabo el cliente, HP se hará cargo de todos los gastos de envío y devolución de componentes

Seite 99

Support and other resources 95 Opcional – Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas para o reparo feito pel

Seite 100 - Index 100

Support and other resources 96

Seite 101 - Index 101

Support and other resources 97

Seite 102 - Index 102

Acronyms and abbreviations 98 Acronyms and abbreviations ACU Array Configuration Utility ADU Array Diagnostics Utility ASR Automatic Server Recove

Seite 103 - Index 103

Acronyms and abbreviations 99 POST Power-On Self Test PPM processor power module RBSU ROM-Based Setup Utility RDP Rapid Deployment Pack SAS seri

Kommentare zu diesen Handbüchern

Keine Kommentare