Hardware options installation 56
Fan population guidelines
Configuration Fan bay 1 Fan bay 2 Fan bay 3 Fan bay 4 Fan bay 5 Fan bay 6
One processor,
nonredundant
Blank Fan Blank Fan Fan Fan
One processor, redundant
Fan Fan Blank Fan Fan Fan
Two processor, nonredundant
Fan Fan Fan Fan Fan Blank
Two processor, redundant
Fan Fan Fan Fan Fan Fan
In a redundant fan mode:
o If one fan fails, the system continues to operate without redundancy. This condition is indicated by
a flashing amber Health LED.
o If two fans fail, the system shuts down.
The minimum fan requirement to make this server bootable is four fans in bays 2, 4, 5, and 6.
Installing a hot-plug fan module if the server is installed in a
ball-bearing rail system with the cable management arm
CAUTION: To prevent the potential for thermal damage and system shutdown, ensure that a
functioning server has all feature bays populated with the required component or blank and the
access panel is installed within 60 seconds of being serviced.
1. Pull down the quick release levers on each side of the server.
WARNING: To reduce the risk of personal injury or equipment damage, be sure that the rack is
adequately stabilized before extending a component from the rack.
2. Extend the server on the rack rails until the server rail-release latches engage.
If the server does not extend from the rack, use a T-25 Torx screwdriver to loosen the screws located
within the lever housing.
3. Open the latch, slide the access panel to the rear of the chassis, and then remove the access panel.