Sense
key
ASC ASCQ
Messag e name / description
5
26 00
INVALID FIELD IN PARAMETER LIST
• Verify Mode Select page fields.
• Verify that fields comply with comm and format d escribed in this
guide.
• Verify that the host software application is supported, has up-to-date
patches, and is correctly confi gured.
• Verify that the library and its components have the current firmw are.
5
26 02
PARAMETER VALUE INVALID
• Verify Mode Select page fields.
• Verify that fields comply with comm and format d escribed in this
guide.
This response is also returned for commands issued to the diagnostic
interface of the library if an invalid parameter is sent.
• Verify that the host software application is supported, has up-to-date
patches, and is correctly confi gured.
• Verify that the library and its components have the current firmw are.
5
30 03
CLEANING CARTRIDGE INSTALLED
A cleaning cartridge cannot be removed from a drive because it is being
used in a cleaning operation. A cartridge cannot be placed into the
drive because the drive is being cleaned. A cartridge cannot be placed
into an
empty storage element because it is reserved for a cleaning
cartri
dge that is currently in use in a drive cleaning operation.
5
39 00
SAVING PAR AM ETERS NOT SUPPORTED
• Verify Save Parameter field i n the Mode Select page complies with
the command format described in this guide.
• Verify that the host software application is supported, has up-to-date
patches, and is correctly confi gured.
• Verify that the library and its components have the current firmw are.
5
53 02
MEDIUM REMOVAL PREVENTED
Prevent Medium Removal command was executed and command
wasreceivedtoexportcartridge. Retrymovecommandusingyour
application software.
5
80 01
TRA
NSFER FULL - COMMAND CAN NOT BE EXECUTED
Pic
ker has cartridge in it.
• Mov
e cartridge to empty storage element using your application
software. Retry command.
• As a last resort, manually remove the tape from the picker.
5
80 2 2
ELEMENT CONTENTS UNKNOWN
The contents of an element address are unknown. Re-inventory the
library.
5
81 C0
TRA NSPORT FULL
The picker contains a cartridge.
• Issue a command to retrieve the cartridge from the picker and place
it in either a bin or a tape drive.
• As a last resort, manually remove the tape from the picker.
5
81 E0
PICKER INVALI D STA RT CONDITION
Picker hardware condition is unknown. Run the Robotics to Home
Position test from the OCP.
HP StorageWorks
117
Kommentare zu diesen Handbüchern