102 Operating Requirements
Table 9 Cable Plant Specifications: 50-Micron Multimode (500m, 100MB/sec)
Non-OFC Operation
Specification Units Value
Fiber type Multimode; graded index
Fiber core micron 50 (nominal)
Fiber Bandwidth (1 km) MHz > 500 @ 850nm
Fiber Dispersion Ps/nm Not applicable
Return loss of cable plant with receiver connected dB > 12
Return loss of each individual connector or splice dB > 26
Cable plant loss dB < 6
Table 10 Cable Plant Specifications: 62.5-Micron Multimode (175m, 100MB/sec)
Non-OFC Operation
Specification Units Value
Fiber type Multimode; graded index
Fiber core micron 62.5 (nominal)
Fiber Bandwidth (1 km) MHz > 160 @ 850nm
Fiber Dispersion Ps/nm Not applicable
Return loss of cable plant with receiver connected dB > 12
Return loss of each individual connector or splice dB > 26
Cable plant loss dB < 6