Jukebox SCSI-2 Command Set
Receive Diagnostic Results Command (1CH)
Chapter 33-34
Hardware Error
Code Code is generated only if an unrecoverable error occurs
(See Table B-7 on page B-19).
FRU 1 The FRU most likely to be at fault (See Table C-1 on
page C-2 or Table C-2 on page C-4).
FRU 2 The second most likely FRU to be at fault. (See
Table C-1 on page C-2 or Table C-2 on page C-4).
FRU 3 The third most likely FRU to be at fault (See Table C-1
on page C-2 or Table C-2 on page C-4).
Test Number The diagnostic test number. This will not be a sequence
number, but the specific test that failed. Refer to
Table B-12 on page B-40 for a list of the jukebox
diagnostic tests.
Parameters Additional parameters as defined for individual tests.
There may be several like components in a unit. These components may
have a common FRU number. When it is possible to detect which of these
FRUs may be at fault, the error code field reflects the one to check.
Table 3-30 Receive Diagnostic Results Command CDB
Byte 7 6 5 4 3 2 1 0
0 Reserved (0)
1 Hardware Error Code
2 FRU 1
3 FRU 2
4 FRU 3
5 Number of the Test that Failed
6-13 Parameters