Switch Command Interface (SWCI)
ServerNet Nomadic Disk (Release 2) User’s Guide523968-001
6-27
Application Initialization Error Messages
Cause. SWCI could not successfully access its startup message to obtain file
input/output parameters.
Effect. SWCI stops.
Recovery. Restart SWCI.
Cause. The switch module device specified for SWCI is a terminal device (device type
6), but not an asynchronous serial port (subtype 0).
Effect. SWCI stops.
Recovery. Check that you have specified a valid switch module device name. Check
the configuration of the WAN profile that specifies the device subtype. If the PROFILE
specifies a wrong device subtype, reconfigure the switch module device with the
correct device subtype. Then, restart SWCI.
Cause. The switch module device specified for SWCI is not a terminal device (device
type 6).
Effect. SWCI stops.
Recovery. Check that you have specified a valid switch module device name. Check
the configuration of the WAN profile that specifies the device type. If the PROFILE
specifies a wrong device type, reconfigure the switch module device with the correct
device type. Then, restart SWCI.
Cause. The TACL RUN command used to start SWCI is incorrectly specified; this
message displays the correct command syntax.
Effect. SWCI stops.
Recovery. Retry the TACL RUN command with the correct syntax.
Startup message not found.
Switch comm port switch-comm-port-name: invalid device
subtype.
Switch comm port switch-comm-port-name: invalid device type.
Usage: $SYSTEM.SYSnn.SWCI switch-comm-port-name.