Hp ProLiant ML110 G6 Server Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Computerhardware Hp ProLiant ML110 G6 Server herunter. HP ProLiant ML110 G6 Server User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 109
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
HP ProLiant ML100 Series Server
User Guide
for HP ProLiant ML110 G6 and HP ProLiant ML150 G6 Servers
Abstract
This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the
servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels.
Part Number: 501528-006
April 2012
Edition: 6
Seitenansicht 0
1 2 3 4 5 6 ... 108 109

Inhaltsverzeichnis

Seite 1 - User Guide

HP ProLiant ML100 Series Server User Guide for HP ProLiant ML110 G6 and HP ProLiant ML150 G6 Servers Abstract This document is for the person who i

Seite 2

Setup 10 In a tower configuration, leave at least a 7.6-cm (3.0-in) clearance space at the front and back of the server for proper ventilation. Rack

Seite 3 - Contents

Technical support 100 Opcional – Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas para o reparo feito pelo cliente

Seite 4 - Contents 4

Technical support 101

Seite 5 - Contents 5

Technical support 102

Seite 6 - Contents 6

Acronyms and abbreviations 103 Acronyms and abbreviations ACU Array Configuration Utility AMP Advanced Memory Protection CS cable select DAT digi

Seite 7 - Operations

Acronyms and abbreviations 104 PCI-X peripheral component interconnect extended PDU power distribution unit POST Power-On Self Test PPM processor

Seite 8

Documentation feedback 105 Documentation feedback HP is committed to providing documentation that meets your needs. To help us improve the documenta

Seite 9 - Optimum environment

Index 106 A access panel 7 acoustics statement for Germany 93 application software problems 80 Array Configuration Utility (ACU) 39 AT comma

Seite 10 - Temperature requirements

Index 107 Federal Communications Commission (FCC) notice 88, 89 firmware, updating 50, 80 firmware, version 50, 67, 82 flash ROM 80 G genera

Seite 11 - Power requirements

Index 108 P patches 79 PCI boards 65 phone numbers 83, 95 POST problems flowchart 57 power cord 48, 93 power distribution unit (PDU) 11

Seite 12 - Registering the server

Index 109 UPS (uninterruptible power supply) 11, 63 USB CD-ROM drive 44, 45 USB devices 44, 45 USB support 41 utilities 38 V ventilation

Seite 13 - Processor option

Setup 11 CAUTION: To reduce the risk of damage to the equipment when installing third-party options: • Do not permit optional equipment to impede

Seite 14

Setup 12 Rack warnings WARNING: To reduce the risk of personal injury or damage to the equipment, be sure that: • The leveling jacks are extend

Seite 15

Hardware options installation 13 Hardware options installation Introduction If more than one option is being installed, read the installation instru

Seite 16

Hardware options installation 14 5. Open the processor locking lever and the processor socket retaining bracket. Do not remove the processor socket

Seite 17 - G6 Servers)

Hardware options installation 15 7. Align the processor installation tool with the socket, and then install the processor. THE PINS ON THE SYSTEM BO

Seite 18

Hardware options installation 16 8. Press the tabs on the processor installation tool to separate it from the processor, and then remove the tool.

Seite 19

Hardware options installation 17 13. For ML150 G6 Servers, do one of the following: o Close or install the tower bezel, as needed. o Slide the ser

Seite 20

Hardware options installation 18 Removable media device option (ML110 G6 servers) This process only represents one installation method. For instruct

Seite 21 - DIMM identification

Hardware options installation 19 8. Connect the data and power cables. 9. Connect the cables to the system board or to an expansion board, as dire

Seite 22

© Copyright 2009, 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warr

Seite 23

Hardware options installation 20 4. Press the fan holder release tab, and then remove the fan holder. 5. Remove the bezel blank. HP recommends tha

Seite 24 - Memory configurations

Hardware options installation 21 13. Power up the server (on page 7). Memory options (ML110 G6 servers) The memory subsystem in this server support

Seite 25

Hardware options installation 22 IMPORTANT: This server does not support mixing RDIMMs and UDIMMs. Attempting to mix these two types causes the se

Seite 26 - Expansion board options

Hardware options installation 23 • Two DIMMs (interleaving) install in slot 2 and slot 4 for optimal performance. Memory options (ML150 G6 servers

Seite 27

Hardware options installation 24 Dual- and quad-rank DIMMs provide the greatest capacity with the existing memory technology. For example, if curren

Seite 28

Hardware options installation 25 Advanced Memory Protection options are configured in RBSU. If the requested AMP mode is not supported by the instal

Seite 29 - Installing DIMMs

Hardware options installation 26 Populated slots (per channel) Rank Speeds supported (MHz) 1 Single- or dual-rank 800, 1333, 1066 1 Quad-rank 800

Seite 30

Hardware options installation 27 o HP ProLiant ML110 G6 server o HP ProLiant ML150 G6 server CAUTION: To prevent improper cooling and thermal

Seite 31

Hardware options installation 28 6. Remove the expansion slot cover. IMPORTANT: It may be necessary to remove the slot cover next to the slot i

Seite 32

Hardware options installation 29 13. Connect any required external cables to the expansion board. 14. Power up the server (on page 7). Installing

Seite 33

Contents 3 Contents Operations...

Seite 34

Hardware options installation 30 1. Power down the server (on page 7). 2. For ML110 G6 servers, extend the server from the rack. 3. For ML150 G6 s

Seite 35

Hardware options installation 31 CAUTION: After the server is powered down, wait 15 seconds and then check the amber LED before unplugging the cab

Seite 36

Hardware options installation 32 7. Connect the cable to the cache module. 8. Install the battery pack. 9. Connect the cable to the controller.

Seite 37

Hardware options installation 33 Installing the FBWC module and capacitor pack To install the component: CAUTION: The cache module connector doe

Seite 38 - ROM-Based Setup Utility

Hardware options installation 34 9. Install the cache module. 10. Install the capacitor pack. 11. Route the cable. 12. Install the access panel

Seite 39 - Array Configuration Utility

Hardware options installation 35 2. Retaining the recovery key/password (on page 37). 3. Enabling the Trusted Platform Module (on page 37). Enablin

Seite 40 - HP Insight Diagnostics

Hardware options installation 36 CAUTION: Any attempt to remove an installed TPM from the system board breaks or disfigures the TPM security rivet

Seite 41 - Management tools

Hardware options installation 37 Retaining the recovery key/password The recovery key/password is generated during BitLocker™ setup, and can be save

Seite 42 - Keeping the system current

Software and configuration utilities 38 Software and configuration utilities ROM-Based Setup Utility RBSU, an embedded configuration utility, perfor

Seite 43 - Embedded SATA RAID feature

Software and configuration utilities 39 NOTE: If the boot drive is not empty or has been written to in the past, ORCA does not automatically confi

Seite 44 - Required hardware

Contents 4 Retaining the recovery key/password ... 37

Seite 45 - Creating a diskette image

Software and configuration utilities 40 • Remains available any time that the server is on • Displays on-screen tips for individual steps of a con

Seite 46

Software and configuration utilities 41 Management tools ROMPaq utility The ROMPaq utility enables you to upgrade the system firmware (BIOS). To upg

Seite 47 - Troubleshooting

Software and configuration utilities 42 Legacy USB support provides USB functionality in environments where USB support is not available normally. S

Seite 48 - Warnings and cautions

Software and configuration utilities 43 IMPORTANT: Always perform a backup before installing or updating device drivers. Operating System Versi

Seite 49 - Symptom information

Software and configuration utilities 44 Creating a RAID volume 1. Enable SATA RAID functionality in RBSU ("Enabling the SATA RAID feature in R

Seite 50 - Common problem resolution

Software and configuration utilities 45 USB diskette and CD-ROM drives For driver installation purposes, a USB diskette drive and USB CD-ROM drive a

Seite 51 - DIMM handling guidelines

Software and configuration utilities 46 IMPORTANT: The LO100i option kit is required to use the Virtual Floppy feature. For more information, see

Seite 52 - Troubleshooting flowcharts

Troubleshooting 47 Troubleshooting Pre-diagnostic steps WARNING: To avoid potential problems, ALWAYS read the warnings and cautionary informatio

Seite 53 - General diagnosis flowchart

Troubleshooting 48 This symbol indicates the presence of a hot surface or hot component. If this surface is contacted, the potential for injury e

Seite 54

Troubleshooting 49 20.41-27.22 kg 47.18-60 lb WARNING: To reduce the risk of personal injury or damage to the equipment: • Observe local occupa

Seite 55 - Power-on problems flowchart

Contents 5 System open circuits and short circuits ...

Seite 56

Troubleshooting 50 6. Collect all tools and utilities, such as a Torx screwdriver, loopback adapters, ESD wrist strap, and software utilities, neces

Seite 57 - POST problems flowchart

Troubleshooting 51 HP offers a subscription service that can provide notification of firmware updates. For more information, see "Subscriber&ap

Seite 58

Troubleshooting 52 Online/activity LED (green) Fault/UID LED (amber/blue) Interpretation On, off, or flashing Alternating amber and blue The dr

Seite 59 - OS boot problems flowchart

Troubleshooting 53 Start diagnosis flowchart Use the following flowchart and table to start the diagnostic process. Item See 1 "General di

Seite 60 - • Redundancy failure

Troubleshooting 54 Item See 4 The most recent version of a particular server or option firmware is available on the HP website (http://www.hp.com/s

Seite 61 - Hardware problems

Troubleshooting 55 Power-on problems flowchart Symptoms: • The server does not power on. • The system power LED is off or amber.

Seite 62 - Power problems

Troubleshooting 56 NOTE: For the location of server LEDs and information on their statuses, refer to the server documentation. Possible causes:

Seite 63 - General hardware problems

Troubleshooting 57 POST problems flowchart Symptoms: • Server does not complete POST NOTE: The server has completed POST when the system at

Seite 64 - Unknown problem

Troubleshooting 58 Item See 1 Server maintenance and service guide, located on the Easy Set-up CD or the HP website (http://www.hp.com/products/s

Seite 65 - Third-party device problems

Troubleshooting 59 OS boot problems flowchart Symptom: Server does not boot a previously installed operating system. Possible causes: • Corrupted o

Seite 66 - Internal system problems

Contents 6 Before you contact HP ...

Seite 67 - Diskette drive problems

Troubleshooting 60 Server fault indications flowchart Symptom: Server boots, but the internal health LED or external health LED is red or amber.

Seite 68 - Hard drive problems

Troubleshooting 61 • System overtemperature condition Item See 1 Server maintenance and service guide, located on the Easy Set-up CD or the HP

Seite 69 - Data is inaccessible

Troubleshooting 62 Internal system problems (on page 66) System open circuits and short circuits (on page 72) External device problems (on page 72)

Seite 70 - Memory problems

Troubleshooting 63 UPS problems UPS is not working properly Action: 1. Be sure the UPS batteries are charged to the proper level for operation. See

Seite 71 - Processor problems

Troubleshooting 64 2. Refer to the release notes included with the hardware to be sure the problem is not caused by a last minute change to the hard

Seite 72 - External device problems

Troubleshooting 65 CAUTION: Only authorized technicians trained by HP should attempt to remove the system board. If you believe the system board r

Seite 73 - Audio problems

Troubleshooting 66 Internal system problems CD-ROM and DVD drive problems System does not boot from the drive Action: 1. Be sure the drive boot ord

Seite 74 - Modem problems

Troubleshooting 67 DAT drives require cleaning every 8 to 25 hours of use or they may fail intermittently when using marginal or bad media. Be sure

Seite 75

Troubleshooting 68 2. Check for and disconnect any non-bootable USB devices. Diskette drive cannot write to a diskette Action: 1. If the diskette

Seite 76 - Network controller problems

Troubleshooting 69 No hard drives are recognized Action: 1. Be sure no power problems (on page 62) exist. 2. Check for loose connections (on page

Seite 77

Operations 7 Operations Power up the server To power up the server, press the Power On/Standby button. Power down the server WARNING: To reduce

Seite 78 - Software problems

Troubleshooting 70 Server response time is slower than usual Action: Be sure the hard drive is not full, and increase the amount of free space on th

Seite 79 - Operating system updates

Troubleshooting 71 Server fails to recognize existing memory Action: 1. Reseat the memory. Use care when handling DIMMs ("DIMM handling guidel

Seite 80 - Firmware maintenance

Troubleshooting 72 CAUTION: Removal of some processors and heatsinks require special considerations for replacement, while other processors and he

Seite 81 - Types of ROM

Troubleshooting 73 1. Power up the monitor and be sure the monitor light is on, indicating that the monitor is receiving power. 2. Be sure the mo

Seite 82 - Drivers

Troubleshooting 74 Printer problems Printer does not print Action: 1. Be sure the printer is powered up and online. 2. Be sure no loose connection

Seite 83 - Contacting HP

Troubleshooting 75 No response occurs when you type AT commands Action: Reconfigure the COM port address for the modem. 1. Be sure the communicatio

Seite 84 - Microsoft® operating systems

Troubleshooting 76 2. Be sure no line interference exists. Retry the connection by dialing the number several times. If conditions remain poor, cont

Seite 85 - Linux operating systems

Troubleshooting 77 3. Be sure the network cable is working by replacing it with a known functional cable. 4. Be sure a software problem has not cau

Seite 86 - Battery

Troubleshooting 78 Problems are occurring with the network interconnect blades Action: Be sure the network interconnect blades are properly seated a

Seite 87 - Battery 87

Troubleshooting 79 Operating system updates Use care when applying operating system updates (Service Packs, hotfixes, and patches). Before updating

Seite 88 - FCC rating label

Operations 8 Remove the tower bezel (ML110 G6 servers) 1. Remove the access panel (on page 7). 2. To release the bezel, push the left side of the

Seite 89 - Modifications

Troubleshooting 80 Linux operating systems For troubleshooting information specific to Linux operating systems, refer to the Linux for ProLiant webs

Seite 90 - • EMC Directive 2004/108/EC

Troubleshooting 81 The process of updating system or option firmware is referred to as a flash process or flashing the ROM. A firmware or ROM flash

Seite 91 - Korean notice

Troubleshooting 82 To flash the ROM using ROMPaq: 1. Download the system ROMPaq utility diskette or USB drive key for each target server. ROMPaq do

Seite 92 - Battery replacement notice

Troubleshooting 83 Contacting HP Contacting HP technical support or an authorized reseller (on page 83) Server information you need Operating syste

Seite 93

Troubleshooting 84 • Specific software information: o Operating system information ("Operating system information you need" on page 84)

Seite 94 - Electrostatic discharge

Troubleshooting 85 Linux operating systems Collect the following information: • Operating system distribution and version Look for a file named /et

Seite 95 - Technical support

Battery 86 Battery If the server no longer automatically displays the correct date and time, you may need to replace the battery that provides power

Seite 96 - Technical support 96

Battery 87 To replace the component, reverse the removal procedure. For more information about battery replacement or proper disposal, contact an au

Seite 97 - Customer Self Repair

Regulatory compliance notices 88 Regulatory compliance notices Regulatory compliance identification numbers For the purpose of regulatory compliance

Seite 98 - Technical support 98

Regulatory compliance notices 89 radio communications. However, there is no guarantee that interference will not occur in a particular installation.

Seite 99 - Reparo feito pelo cliente

Setup 9 Setup Optional installation services Delivered by experienced, certified engineers, HP Care Pack services help you keep your servers up and

Seite 100 - Technical support 100

Regulatory compliance notices 90 This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. C

Seite 101 - Technical support 101

Regulatory compliance notices 91 This symbol on the product or on its packaging indicates that this product must not be disposed of with your other

Seite 102 - Technical support 102

Regulatory compliance notices 92 Class B equipment Chinese notice Class A equipment Laser compliance This product may be provided with an optica

Seite 103 - Acronyms and abbreviations

Regulatory compliance notices 93 For more information about battery replacement or proper disposal, contact an authorized reseller or an authorized

Seite 104

Electrostatic discharge 94 Electrostatic discharge Preventing electrostatic discharge To prevent damaging the system, be aware of the precautions yo

Seite 105 - Documentation feedback

Technical support 95 Technical support HP contact information For United States and worldwide contact information, see the Contact HP website (http:

Seite 106 - Index 106

Technical support 96 providers or service partners) identifies that the repair can be accomplished by the use of a CSR part, HP will ship that part

Seite 107 - Index 107

Technical support 97 Pour plus d'informations sur le programme CSR de HP, contactez votre Mainteneur Agrée local. Pour plus d'informations

Seite 108 - Index 108

Technical support 98 HINWEIS: Einige Teile sind nicht für Customer Self Repair ausgelegt. Um den Garantieanspruch des Kunden zu erfüllen, muss das

Seite 109 - Index 109

Technical support 99 sustituciones que lleve a cabo el cliente, HP se hará cargo de todos los gastos de envío y devolución de componentes y escogerá

Verwandte Modelle: ProLiant ML150 G6 Server

Kommentare zu diesen Handbüchern

Keine Kommentare