  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen

Inhaltsverzeichnis

Seite 1 - User Guide

HP ProLiant DL740 Server User Guide June 2003 (Second Edition) Part Number 270854-002 HP CONFIDENTIAL Writer: Anna Roberts File Name: a-frnt.

Seite 2

About This Guide This guide provides step-by-step instructions for installation, and reference information for operation, troubleshooting, and futur

Seite 3 - Contents

5 Installing Hardware Options, Hot-Plug The following instructions are provided as an overview for installing hardware option upgrades that are hot-p

Seite 4

Installing Hardware Options, Hot-Plug Hot Plug RAID Memory The ProLiant DL740 server supports up to 40 GB of Hot Plug RAID Memory using industry-stand

Seite 5

Installing Hardware Options, Hot-Plug Memory Cartridge Components The following figure and table show the various components of the memory cartridges.

Seite 6

Installing Hardware Options, Hot-Plug The ProLiant DL740 server has eight memory banks, each consisting of five DIMMs installed across the five memory

Seite 7

Installing Hardware Options, Hot-Plug Memory Cartridge LED Indicators The ProLiant DL740 server has LEDs for each of the memory cartridges. These LEDs

Seite 8

Installing Hardware Options, Hot-Plug Each memory cartridge has two LEDs located on it. The memory cartridge LEDs are used to determine the power stat

Seite 9

Installing Hardware Options, Hot-Plug LED Indicator State Definitions HP ProLiant DL740 Server User Guide 5-7 HP CONFIDENTIAL Writer: Anna Roberts

Seite 10 - About This Guide

Installing Hardware Options, Hot-Plug Accessing the DIMMs To access the DIMMs in the server, you must remove the memory cartridge. The Hot Plug RAID M

Seite 11

Installing Hardware Options, Hot-Plug Figure 5-5: Removing the memory cartridge DIMM Overview The ProLiant DL740 server has five memory cartridges,

Seite 12 - Symbols in Text

Installing Hardware Options, Hot-Plug Figure 5-6: DIMM socket location Table 5-3: DIMM Socket Location Item Description Bank 1 DIMM socket 1 D

Seite 13 - Server Labels

About This Guide This symbol indicates the presence of hazardous energy circuits or electric shock hazards. Refer all servicing to qualified personn

Seite 14 - Related Documents

Installing Hardware Options, Hot-Plug Installing DIMMs in the Memory Cartridge CAUTION: When handling a DIMM, be careful not to touch any of the co

Seite 15 - HP Website

Installing Hardware Options, Hot-Plug 3. Be sure that all of the DIMM socket levers are rotated inward. 5-12 HP ProLiant DL740 Server User Guide H

Seite 16 - Authorized Reseller

Installing Hardware Options, Hot-Plug Hot-Replacing Memory If there is a problem with a DIMM in the server, the DIMM status LEDs will illuminate as ei

Seite 17 - [email protected]

Installing Hardware Options, Hot-Plug To replace DIMMs: 1. Remove the memory cartridge by following the procedure in the “Removing the Memory Cartrid

Seite 18 - Server Features

Installing Hardware Options, Hot-Plug Hot-Adding Memory For the hot-add feature to work on the ProLiant DL740 server, the operating system must have d

Seite 19

Installing Hardware Options, Hot-Plug To install additional DIMMs in the server, you must add them in bank pairs across all five of the memory cartrid

Seite 20

Installing Hardware Options, Hot-Plug e. Lock the memory cartridge by sliding the cartridge lock to the closed position. f. The system will rebuild

Seite 21

Installing Hardware Options, Hot-Plug Hot-Upgrading Memory For the hot-upgrade feature to work on the ProLiant DL740 server, the operating system must

Seite 22

Installing Hardware Options, Hot-Plug 1. Begin with memory cartridge 1: a. Unlock the cartridge and lift it out of the server by following the proce

Seite 23 - Processors

Installing Hardware Options, Hot-Plug IMPORTANT: The memory cartridge power LED must be illuminated solid before you can unlock the next memory cart

Seite 24 - Hot Plug RAID Memory

About This Guide Rack Stability WARNING: To reduce the risk of personal injury or damage to the equipment, be sure that: • The leveling jacks are

Seite 25

Installing Hardware Options, Hot-Plug Non-RAID Memory Support Non-RAID memory configuration is now more user-friendly in the ProLiant DL740 Server wi

Seite 26

Installing Hardware Options, Hot-Plug Mass Storage The following sections provide an overview for installing hard disk drives. The ProLiant DL740 serv

Seite 27 - PCI Hot Plug

Installing Hardware Options, Hot-Plug Hot-Plug SCSI Hard Drive LED Indicators The hot-plug SCSI hard drive LEDs, located on each physical drive, are v

Seite 28 - Disk Controller

Installing Hardware Options, Hot-Plug Figure 5-10: SCSI hard drive LEDs 5-24 HP ProLiant DL740 Server User Guide HP CONFIDENTIAL Writer: Anna Rob

Seite 29 - Universal Media Bay

Installing Hardware Options, Hot-Plug Guidelines for Installing Hot-Plug SCSI Hard Drives Follow these guidelines when adding SCSI hard drives: • A m

Seite 30 - Supported Interfaces

Installing Hardware Options, Hot-Plug Installing a Hot-Plug SCSI Hard Disk Drive CAUTION: Before adding or removing any hot-plug SCSI drives, consu

Seite 31 - Supported Operating Systems

Installing Hardware Options, Hot-Plug 3. Insert the new hot-plug drive into the empty drive bay, pushing until the unit is securely seated (1). 4. S

Seite 32 - SmartStart

Installing Hardware Options, Hot-Plug Advanced Data Guarding When a hot-pluggable disk drive is removed, although the system is functionally operation

Seite 33

Installing Hardware Options, Hot-Plug • Never turn a disk enclosure off while the initiator or controller is powered on or active. Doing so can cause

Seite 34

Installing Hardware Options, Hot-Plug Removing the DVD/CD-ROM Drive The universal media bay supports hot-pluggable IDE devices and ships standard with

Seite 35

About This Guide Server Labels A significant amount of server configuration and options installation information is provided on the server labels. As

Seite 36 - Advanced Data Guarding

Installing Hardware Options, Hot-Plug Installing a StorageWorks Hot-Plug Tape Drive To install a StorageWorks hot-plug tape drive in the drive cage: 1

Seite 37 - HP Utilities for Linux

Installing Hardware Options, Hot-Plug Installing a Hot-Plug Power Supply The ProLiant DL740 server ships with two hot-plug power supplies. The system

Seite 38

Installing Hardware Options, Hot-Plug Figure 5-15: Removing a power supply 3. Remove the protective covers from the connector on the new power supp

Seite 39

Installing Hardware Options, Hot-Plug 4. Slide the hot-plug power supply into the power supply cage until the supply is seated securely (1). This act

Seite 40 - Software Security

Installing Hardware Options, Hot-Plug Power Supply LED Indicators Each power supply has status LEDs. Refer to Figure 5-17 and Table 5-4 for a detailed

Seite 41 - Hardware Security

Installing Hardware Options, Hot-Plug Table 5-4: Power Supply LEDs Item Condition Meaning Green blinking AC power is connected to this power supply

Seite 42 - Routine Maintenance

Installing Hardware Options, Hot-Plug PCI-X Hot Plug I/O Expansion Boards The ProLiant DL740 server supports PCI-X Hot Plug. PCI-X Hot Plug and the op

Seite 43 - Warranty

Installing Hardware Options, Hot-Plug For information about specific operating systems with PCI-X Hot Plug support, refer to the operating system supp

Seite 44

Installing Hardware Options, Hot-Plug WARNING: To reduce the risk of personal injury from hot surfaces, allow the internal system components to coo

Seite 45 - Rack Installation Overview

Installing Hardware Options, Hot-Plug PCI Hot Plug Button The PCI Hot Plug button provides PCI Hot Plug hardware control without requiring you to firs

Seite 46 - Selecting a Site

About This Guide Related Documents For additional information on the topics covered in this guide, refer to the following documentation: • Rack Resou

Seite 47

Installing Hardware Options, Hot-Plug Figure 5-20: PCI Hot Plug LEDs inside the host module Table 5-6 provides a description and slot status for the

Seite 48 - Power Requirements

Installing Hardware Options, Hot-Plug Table 5-6: PCI Hot Plug LEDs and Button Amber LED OK to Open Slot Condition and Status Off Slot does not r

Seite 49

Installing Hardware Options, Hot-Plug PCI-X Hot Plug Operating System Support Software support is an integral part of PCI-X Hot Plug. HP, in partnersh

Seite 50 - Grounding Requirements

Installing Hardware Options, Hot-Plug Software Components PCI Hot Plug support for Windows 2000 is provided through the PCI Hot Plug Filter driver. Th

Seite 51 - Temperature Requirements

Installing Hardware Options, Hot-Plug Software Components PCI Hot Plug support for Windows Server 2003 is provided through the PCI Hot Plug Filter dri

Seite 52 - Shipping Box Contents

Installing Hardware Options, Hot-Plug Adding a PCI Hot Plug Expansion Board The PCI/PCI-X slots of the I/O board are hot-plug-capable and support a va

Seite 53

Installing Hardware Options, Hot-Plug 4. Press on the top (1) of the appropriate expansion slot release lever and open the lever toward the rear (2)

Seite 54 - Warnings and Precautions

Installing Hardware Options, Hot-Plug 6. Insert the PCI/PCI-X expansion board into the appropriate expansion slot, pushing firmly until the board is

Seite 55

Installing Hardware Options, Hot-Plug HP has designed a self-latching slot-keeper feature to accommodate full-length expansion boards. Be sure that th

Seite 56

Installing Hardware Options, Hot-Plug 9. Activate power to the slot through the PCI Hot Plug software application or by pressing the PCI Hot Plug but

Seite 57

About This Guide Getting Help If you have a problem and have exhausted the information in this guide, you can get further information and other help i

Seite 58

Installing Hardware Options, Hot-Plug Removing or Replacing a PCI Hot Plug Expansion Board To remove or replace a PCI Hot Plug expansion board: 1. Op

Seite 59

Installing Hardware Options, Hot-Plug 4. Press on the top (1) of the appropriate expansion slot release lever and open the slot-keeper lever toward t

Seite 60

Installing Hardware Options, Hot-Plug Replacing Hot-Plug Fans The ProLiant DL740 server ships with two hot-plug fans. Fan 1 is closest to the front of

Seite 61

Installing Hardware Options, Hot-Plug The ProLiant DL740 server comes equipped with fan attention LEDs located on the front of the server, as shown in

Seite 62 - Attaching the Server Rails

Installing Hardware Options, Hot-Plug To replace a hot-plug fan: 1. Open the top access panels. 2. Squeeze the locking latch (1) with your fingers,

Seite 63 - Lightening the Chassis

Installing Hardware Options, Hot-Plug 5-56 HP ProLiant DL740 Server User Guide HP CONFIDENTIAL Writer: Anna Roberts File Name: f-ch5 Installing Har

Seite 64

6 Cabling the Server After the server has been installed in a rack and any additional server options installed, cable the server. Peripheral Devices

Seite 65

Cabling the Server Figure 6-1: Rear panel connectors Table 6-1: Rear Panel Connectors Item Component Item Component 1 AC power port 7 Mouse co

Seite 66

Cabling the Server Power Cables WARNING: To reduce the risk of electric shock or damage to the equipment: • Install the power supply before connec

Seite 67 - Rack Template

Cabling the Server To connect the AC power cords: 1. Install the power cords into the primary and secondary AC inlets on the rear of the server (1).

Seite 68 - Server Access

About This Guide Authorized Reseller For the name of your nearest authorized reseller: • In the United States, call 1-800-345-1518. • In Canada, cal

Seite 69 - Access Method

Cabling the Server Cable Management System The cable management system is installed on the back of the server mounted in the rack and consists of two

Seite 70

Cabling the Server 2. Install the second reel (labeled with the number 4) to the right side of the server chassis (1) using the thumbscrew (2). Figu

Seite 71 - Accessing the Host Module

Cabling the Server The cable management harness has several metal harness hooks and straps all labeled with numbers. These numbers show the sequence f

Seite 72 - Removing the Host Module

Cabling the Server 3. Match and connect the cable harness hook 1 to the loop labeled 1 on the server chassis. Figure 6-6: Connecting cable harness

Seite 73

Cabling the Server 5. Bundle the server cables together and wrap all the short straps labeled 2 around the cable bundle. Figure 6-7: Bundling cable

Seite 74

Cabling the Server 6. Attach the cable harness hook 3 to reel 3. Figure 6-8: Connecting cable harness hook 3 6-10 HP ProLiant DL740 Server User Gu

Seite 75 - Host Module Components

Cabling the Server 7. Attach the cable harness hook 4 to reel 4. Figure 6-9: Connecting cable harness hook 4 HP ProLiant DL740 Server User Guide 6

Seite 76

Cabling the Server 6-12 HP ProLiant DL740 Server User Guide HP CONFIDENTIAL Writer: Anna Roberts File Name: g-ch6 Cabling the Server.doc Codename:

Seite 77

7 Server Power This chapter provides information about the operation of the server power supplies. The purpose of this chapter is to guide you throug

Seite 78

Server Power System Power Overview The system power in the ProLiant DL740 server does not shut off completely with the front panel Power On/Standby sw

Seite 79

About This Guide Reader’s Comments HP welcomes your comments on this guide. Please send your comments and suggestions by e-mail to ServerDocumentation

Seite 80

Server Power Power Supplies The ProLiant DL740 server can support two hot-plug, redundant power supplies. Refer to Chapter 5 or the option documentat

Seite 81

Server Power Power Supply LED Indicators Each power supply has status LEDs. Refer to Figure 7-2 and Table 7-1 for a detailed description of both indic

Seite 82

Server Power Table 7-1: Power Supply LEDs Item Condition Meaning Green blinking AC power is connected to this power supply. System is in standby mo

Seite 83

Server Power Figure 7-3: System interconnect status LEDs Item Description 1 System interconnect 2 I/O board interconnect 3 Processor board 1 inter

Seite 84 - Intel Xeon Processor MP

Server Power Powering Up the Server When you power up the server, it should go through the following sequence. Record any discrepancies and any error

Seite 85

Server Power — If the system power LED is amber, check the system interconnect status indicators, as explained in the “System Interconnect Status Ind

Seite 86 - Installing a Processor Board

Server Power 4. The system activity LEDs (NIC1, NIC2, and Media) begin to blink in sequence until the memory initialization is complete. Figure 7-5:

Seite 87

Server Power Power-On Self-Test (POST) As the POST process continues during server power-up, you need to check the monitor for the following informati

Seite 88

Server Power Press the F1 key to enter the Memory Configuration Manager. This ROM-Based tool (shown in Figure 7-7) is used to examine and upgrade your

Seite 89 - Non-Hot-Plug I/O Expansion

Server Power 5. Processor initialization information. The number, speed, and cache size of each processor is listed as it initializes. 6. The system

Seite 90

1 Server Features ProLiant DL740 Servers The ProLiant DL740 server, a high-density enterprise-class and datacenter server, delivers 8-way scalable pe

Seite 91 - To add an expansion board:

Server Power HP ProLiant DL740 Server User Guide 7-13 HP CONFIDENTIAL Writer: Anna Roberts File Name: h-ch7 Server Power.doc Codename: Expedition P

Seite 92

8 Configuring the Server This chapter discusses how to configure the ProLiant DL740 server by setting up the server environment, setting up the hard

Seite 93

Configuring the Server Setting Up the Base Environment The ProLiant DL740 comes equipped with updateable, “intelligent” ROM-based configuration utilit

Seite 94

Configuring the Server Figure 8-1: Initial system auto-configuration If the system memory is installed in an unsupported configuration, then the Mem

Seite 95

Configuring the Server Figure 8-2: Boot option screen This screen is only visible for two seconds and allows you to press the F9 key to run RBSU or

Seite 96 - Bypass assembly

Configuring the Server Manual Configuration Pressing the F9 key when prompted during POST launches RBSU, which guides you through the following manual

Seite 97

Configuring the Server 2. Select the operating system of the server. Figure 8-4: Setting the operating system in RBSU 3. After the language and op

Seite 98

Configuring the Server Accessing the System Maintenance Menu The System Maintenance Menu is embedded into the system ROM and replaces the legacy Syste

Seite 99

Configuring the Server Figure 8-6: System prompts after normal POST 8-8 HP ProLiant DL740 Server User Guide HP CONFIDENTIAL Writer: Anna Roberts

Seite 100 - HP CONFIDENTIAL

Configuring the Server System Maintenance Menu After you press the F10 key at the end of POST, the System Maintenance Menu screen is displayed, as sho

Seite 101 - Memory Cartridge Overview

Server Features In addition to Hot Plug RAID Memory, other high-availability features include: • Redundant array of memory with error checking and co

Seite 102 - Memory Cartridge Guidelines

Configuring the Server ROM-Based Setup Utility Select Setup Utility in the System Maintenance Menu to launch RBSU. The main RBSU screen is shown in Fi

Seite 103

Configuring the Server ROM-Based Inspect Utility Select Inspect Utility in the System Maintenance Menu to launch the ROM-Based Inspect Utility shown i

Seite 104 - Table 5-1: DIMM Status LEDs

Configuring the Server ROM-Based Diagnostic Utility Select Diagnostic Utility in the System Maintenance Menu to launch the ROM-Based Diagnostic Utilit

Seite 105

Configuring the Server Memory Diagnostics When you select Memory Diagnostic from the ROM-Based Diagnostic Utility menu, the diagnostic runs until comp

Seite 106

Configuring the Server CPU Diagnostic The CPU diagnostic checks the registers and multiprocessing capability of each of the system processors. The CPU

Seite 107 - Accessing the DIMMs

Configuring the Server Boot Disk Diagnostic The boot disk diagnostic can be used to verify the presence and readiness of a primary boot controller. If

Seite 108 - DIMM Overview

Configuring the Server Configuring the Drive Array Controller If you are using a simple SCSI controller to boot from the internal drives, disregard th

Seite 109

Configuring the Server Alternatively, an Ultra3 SCSI RAID controller can be installed in any PCI/PCI-X slot, bypassing the Smart Array 5i Controller.

Seite 110

Configuring the Server Accessing ORCA After the system has completed POST, press the F8 key for custom configuration or the F7 key to accept the defau

Seite 111

Configuring the Server Using ORCA To configure the drive array controller: CAUTION: If you have installed any previously-used hard drives into the

Seite 112 - Hot-Replacing Memory

© 2002, 2003 Hewlett-Packard Development Group, L.P. Microsoft®, Windows®, and Windows NT® are US registered trademarks of Microsoft Corporation. Int

Seite 113

Server Features In ProLiant DL740 servers, you can access options and accessories easily through a top access panel and two removable modules: The hos

Seite 114 - Hot-Adding Memory

Configuring the Server Array Configuration Utility The Array Configuration Utility (ACU) is an easy-to-use graphical configuration utility to help set

Seite 115

Configuring the Server 4. Select the Array Configuration Utility program. When you start the ACU, the software checks the configuration of each contr

Seite 116

Configuring the Server Logical drive extension allows you to increase the size of existing logical drives 8-22 HP ProLiant DL740 Server User Guide

Seite 117 - Hot-Upgrading Memory

Configuring the Server Array Configuration Replicator Utility The Array Configuration Replicator (ACR) utility enables you to configure Smart Array co

Seite 118

Configuring the Server Installing the Operating System If you are installing the operating system using the SmartStart CD, configure it by using the i

Seite 119

Configuring the Server HP ProLiant DL740 Server User Guide 8-25 HP CONFIDENTIAL Writer: Anna Roberts File Name: i-ch8 Configuring the Server.doc Co

Seite 120 - Non-RAID Memory Support

9 Software Management HP provides several tools that aid in managing and maintaining the ProLiant DL740 server: • Integrated Lights-Out (iLO) Stand

Seite 121 - Mass Storage

Software Management Integrated Lights-Out Integrated Lights-Out (iLO) is a standard feature of selected HP ProLiant servers. iLO provides server healt

Seite 122

Software Management • Virtual media—With the Virtual Floppy Drive, an administrator can easily direct a remote host server to boot and use standard m

Seite 123

Software Management • Virtual Private Network (VPN) support—When used in conjunction with VPN technology, iLO functionality is available around the w

Seite 124

Server Features Figure 1-2: Server front view—module components Item Description 1 Power supply 1 2 Hot-plug hard drives 3 Universal media bay 4 P

Seite 125

Software Management Integrated Lights-Out Security Override The iLO Security Override allows the administrator full access to the iLO processor. Acces

Seite 126

Software Management To set the iLO Security Override Switch: 1. Power down the server and remove AC power cords. Refer to Chapter 7 for instructions.

Seite 127

Software Management In the unlikely event that it is necessary, enabling the iLO Security Override also enables the iLO BootBlock to be flashed. The

Seite 128

Software Management Integration with Insight Manager 7 Full integration is provided for iLO and Insight Manager 7 under key operating environments. Th

Seite 129

Software Management Integrated Management Log The Integrated Management Log (IML) records system events and stores them in an easily viewable form. Th

Seite 130

Software Management Viewing the IML with the Survey Utility The Survey Utility is an online information-gathering agent that runs on servers, gatherin

Seite 131

Software Management Viewing the IML with Insight Manager 7 Insight Manager 7 is a server management tool capable of in-depth fault, configuration, and

Seite 132

Software Management Figure 9-5: Integrated Management Log 4. If a failed component has been replaced, select the event from the list, then click Ma

Seite 133

Software Management Insight Manager 7 Insight Manager 7 is a server management tool capable of in-depth fault, configuration, and performance monitori

Seite 134 - Power Supply LED Indicators

Software Management Survey Utility The Survey Utility is a serviceability tool for Microsoft Windows 2000, Windows Server 2003, and Linux that deliver

Seite 135

Server Features Figure 1-3: Server rear view—module components Item Description 1 System fans 2 AC power ports 3 I/O expansion slots 4 External

Seite 136

Software Management Array Configuration Utility The Array Configuration Utility (ACU) software for Smart Array controllers, the StorageWorks RAID Arra

Seite 137 - PCI Hot Plug Utility

Software Management The first time the ACU is run, if you have not already set up your Web agent password, ACU will launch an applet for setting up yo

Seite 138

Software Management HP ProLiant DL740 Server User Guide 9-17 HP CONFIDENTIAL Writer: Anna Roberts File Name: j-ch9 Software Management.doc Codename

Seite 139 - PCI Hot Plug LED Indicators

A Regulatory Compliance Notices Regulatory Compliance Identification Numbers For the purpose of regulatory compliance certifications and identificati

Seite 140

Regulatory Compliance Notices Federal Communications Commission Notice This equipment has been tested and found to comply with the limits for a Class

Seite 141

Regulatory Compliance Notices Canadian Notice (Avis Canadien) This Class A digital apparatus meets all requirements of the Canadian Interference-Causi

Seite 142

Regulatory Compliance Notices Japanese Notice BSMI Notice A-4 HP ProLiant DL740 Server User Guide HP CONFIDENTIAL Writer: Anna Roberts File Name:

Seite 143

Regulatory Compliance Notices Laser Devices All HP systems equipped with a laser device comply with safety standards, including International Electrot

Seite 144

Regulatory Compliance Notices Power Cords The power cord set included in the server meets the requirements for use in the country where you purchased

Seite 145

Regulatory Compliance Notices HP ProLiant DL740 Server User Guide A-7 HP CONFIDENTIAL Writer: Anna Roberts File Name: k-appa Regulatory Compliance

Seite 146 - for installation

Server Features 1-6 HP ProLiant DL740 Server User Guide HP CONFIDENTIAL Writer: Anna Roberts File Name: b-ch1 Server Features.doc Codename: Expedit

Seite 147

B Electrostatic Discharge To prevent damage to the system, be aware of the following precautions when setting up the system or handling parts. A disc

Seite 148

Electrostatic Discharge B-2 HP ProLiant DL740 Server User Guide HP CONFIDENTIAL Writer: Anna Roberts File Name: l-appb Electrostatic Discharge.doc

Seite 149

C Server Error Messages POST Error Messages All Power-On Self-Test (POST) error messages provided for this server are included in the HP Servers Trou

Seite 150

D LED Indicators and Switches LED Indicators Status LEDs are located on the front, back, and inside of the server. These LEDs communicate the current

Seite 151

LED Indicators and Switches System Power LED Switch Figure D-1 shows the location of the system power LED switch. Figure D-1: System power LED switc

Seite 152 - Replacing Hot-Plug Fans

LED Indicators and Switches Figure D-2 displays the locations of the Unit Identification LED switches on the front and rear of the server. Figure D-2

Seite 153

LED Indicators and Switches Figure D-3: System interconnect LEDs Item Description 1 System interconnect 2 I/O board interconnect 3 Processor board

Seite 154 - To replace a hot-plug fan:

LED Indicators and Switches System Attention LED Indicators Figure D-4: System attention LEDs Item Description 1 Temperature attention 2 Hot-plug f

Seite 155

LED Indicators and Switches System Activity LED Indicators Figure D-5: System activity LEDs Item Description 1 NIC 1 link status activity LED 2 NI

Seite 156 - Cabling the Server

LED Indicators and Switches Hot-Plug SCSI Hard Drive LED Indicators The hot-plug SCSI hard drive LEDs, located on each physical drive, are visible on

Seite 157

Server Features Hot Plug RAID Memory The HP memory RAID technology stands for Redundant Array of Industry-Standard DIMMs. The ProLiant DL740 server su

Seite 158 - Power Cables

LED Indicators and Switches Figure D-7: SCSI hard drive LEDs D-8 HP ProLiant DL740 Server User Guide HP CONFIDENTIAL Writer: Anna Roberts File Na

Seite 159

LED Indicators and Switches Power Supply LED Indicators Each power supply has status LEDs. See Figure D-8 and Table D-1 for a detailed description of

Seite 160 - Cable Management System

LED Indicators and Switches Table D-1: Power Supply LEDs Item Condition Meaning Green blinking AC power is connected to this power supply. System i

Seite 161

LED Indicators and Switches Hot-Plug Fan LED Indicators The ProLiant DL740 server ships with two hot-plug fans. Fan 1 is closest to the front of the s

Seite 162

LED Indicators and Switches PCI Hot Plug LED Indicators The PCI Hot Plug amber and green LEDs provide a visual reference of the status of each slot. T

Seite 163

LED Indicators and Switches Figure D-11: PCI Hot Plug LEDs in the host module A description and slot status for the PCI Hot Plug LEDs and button sho

Seite 164

LED Indicators and Switches Table D-2: PCI Hot Plug LEDs and Button Amber LED OK to Open Slot Condition and Status Off Slot does not require att

Seite 165

LED Indicators and Switches Memory Cartridge LED Indicators Each memory cartridge has two LEDs that indicate its status. Figure D-12: Memory cartrid

Seite 166

LED Indicators and Switches DIMM Status LED Indicators The ProLiant DL740 server has LEDs for each DIMM in the five memory cartridges. These LEDs are

Seite 167

LED Indicators and Switches Table D-4: Memory Cartridge LED State Definitions LED Indicator State Condition Action Solid Cartridge online (normal

Seite 168 - Server Power

Server Features The Hot Plug RAID Memory cartridges are located on the inner right side of the host module. Each memory cartridge contains up to eight

Seite 169 - System Power Overview

LED Indicators and Switches Switches This section contains graphics and tables showing switch location and settings for the host board. I/O Board Conf

Seite 170 - Power Supplies

LED Indicators and Switches HP ProLiant DL740 Server User Guide D-19 HP CONFIDENTIAL Writer: Anna Roberts File Name: n-appd LED Indicators and Swit

Seite 171

E Troubleshooting Information This appendix provides step-by-step instructions about what to try and where to go for help for the most common problem

Seite 172

Troubleshooting Information Server Startup Problems Complete these steps if the server does not start: 1. Be sure that the computer and monitor are p

Seite 173

Troubleshooting Information NOTE: ASR-2 can be enabled to restart your server and automatically load the operating system. If a critical error occur

Seite 174

Troubleshooting Information Diagnosis Steps If your server does not power up or powers up but does not complete the POST, answer the questions in the

Seite 175

Troubleshooting Information Figure E-1: Memory Configuration Manager HP ProLiant DL740 Server User Guide E-5 HP CONFIDENTIAL Writer: Anna Roberts

Seite 176

Troubleshooting Information Table E-2: Did Power Supply Turn On? Check to see if the power supply and system fans are running. Verify this visually.

Seite 177 - Power-On Self-Test (POST)

Troubleshooting Information Table E-3: Are all of the System Interconnect Status LED Indicators Off? Refer to “System Interconnect LED Indicators” i

Seite 178

Troubleshooting Information Table E-3: Are all of the System Interconnect Status LED Indicators Off? continued Refer to “System Interconnect LED Indi

Seite 179 - Figure 7-8: System prompts

Server Features The ProLiant DL740 server has five memory cartridges, each consisting of eight DIMMs. In each memory cartridge, similar DIMMs are inst

Seite 180 - Powering Down the Server

Troubleshooting Information Table E-4: Does the Server Have Video? Answer Possible Reasons The Next Step Yes Video is available for diagnosis.

Seite 181 - Configuring the Server

Troubleshooting Information Table E-5: Are either of the Processor Board attention LED’s located on the front bezel illuminated? Status Action Proce

Seite 182

Troubleshooting Information Table E-5: Are either of the Processor Board attention LED’s located on the front bezel illuminated? continued Status Act

Seite 183

Troubleshooting Information Table E-6: Memory Configuration Guidelines Problem Possible Cause Possible Solution Missing memory cartridge Install al

Seite 184

Troubleshooting Information Table E-7: Problems After Initial Boot Problem Possible Cause Possible Solution SmartStart requirement is not performed.

Seite 185 - Manual Configuration

Troubleshooting Information Table E-7: Problems After Initial Boot continued Problem Possible Cause Possible Solution Required operating system step

Seite 186

Troubleshooting Information HP ProLiant DL740 Server User Guide E-15 HP CONFIDENTIAL Writer: Anna Roberts File Name: o-appe Troubleshooting Informa

Seite 187

F Server Specifications Server Specifications Table F-1: ProLiant DL740 Server Specifications Dimensions Height 7.0 in 17.8 cm Depth 28.5 in

Seite 188

G System Battery This appendix provides information about the ProLiant DL740 server system battery. Internal Battery To remove the internal battery:

Seite 189 - System Maintenance Menu

System Battery G-2 HP ProLiant DL740 Server User Guide HP CONFIDENTIAL Writer: Anna Roberts File Name: q-appg System Battery.doc Codename: Expediti

Seite 190 - ROM-Based Setup Utility

Server Features PCI-X Technology PCI-X technology leverages the wide acceptance of the PCI bus and provides an evolutionary I/O upgrade to conventiona

Seite 191 - ROM-Based Inspect Utility

Index A access panel 3-2 access panels xiv ACR (Array Configuration Replicator) utility 8-23 ADU (Array Diagnostic Utility) C-1 Advanced Dat

Seite 192 - ROM-Based Diagnostic Utility

Index configuration array controller 8-16 features 1-15 installing operating system 8-24 memory cartridges 5-4 overview 8-1 RBSU features

Seite 193

Index H hard drives fault protection 1-19 installing 5-22 LED indicators 5-23, D-7 location 1-4 supported 1-11 VHDCI connector 8-16 hardwa

Seite 194 - Figure 8-12: CPU diagnostic

Index rack considerations 2-10 rack rail assemblies 2-16 storage devices 5-22 tape drive 5-31 Integrated Array Bypass kit 4-12 Integrated Li

Seite 195

Index N native graphical remote console 9-2 network interface controllers (NICs) 1-11 non-hot-plug components expansion boards 4-7 host module

Seite 196

Index R rack preparing server for mounting 2-1 selecting site 2-3 stability considerations 2-10 temperature requirements 2-8 template for 2-

Seite 197

Index SmartStart CD OS installation 8-24 overview 1-15 troubleshooting installation E-13 SmartStart Scripting Toolkit 8-23 SNMP trap delivery

Seite 198 - Figure 8-14: ORCA main menu

Index W warnings electric shock 6-3 rack precautions 2-11 warranty 1-26 Web-based Agents 9-8 websites ACU 9-15 array controllers 8-19 HP

Seite 199

Server Features Network Interface Controllers The ProLiant DL740 server is equipped with two embedded Gigabit Ethernet network interface controllers.

Seite 200 - Array Configuration Utility

Server Features Internal Hot-Plug Drive Bays The internal hot-plug drive bays support four one-inch Ultra3 SCSI hard drives. Drives may be of any stor

Seite 201

HP ProLiant DL740 Server User Guide iii HP CONFIDENTIAL Writer: Anna Roberts File Name: a-frnt.doc Codename: Expedition Part Number: 270854-002 La

Seite 202

Server Features Redundant Hot-Plug Fans ProLiant DL740 servers include 1 + 1 redundant hot-plug fans. If a fan fails, the server generates a system al

Seite 203

Server Features Optional Features The ProLiant DL740 server supports a wide range of server hardware options. HP server options are available from an

Seite 204

Server Features Server Configuration and Management Features HP offers an extensive set of features and tools to support effective server configuratio

Seite 205

Server Features ROM-Based Setup Utility RBSU automatically configures the system based on the selected operating system. RBSU supports a wide range of

Seite 206 - Software Management

Server Features Integrated Lights-Out Standard Management Integrated Lights-Out (iLO) is an HP engineered application-specific integrated circuit (ASI

Seite 207 - Features

Server Features • Alert forwarding and administration • Remote firmware update • SSL security iLO Advanced Features (Optional) The iLO Advanced opt

Seite 208

Server Features Smart Components for Online ROM Flash HP ProLiant DL740 Server User Guide 1-19 HP CONFIDENTIAL Writer: Anna Roberts File Name: b-ch

Seite 209

Server Features Only the Smart Array 5300 Controllers support RAID ADG. The Smart Array 5304/128 is shipped with RAID ADG and is available as an upgra

Seite 210

Server Features HP has an array of Opensource projects for Linux. For more information on HP Opensource projects refer to: opensource.hp.com/ HP only

Seite 211

Server Features Integrated Management Log The Integrated Management Log (IML) records all system events and stores them in an easily viewable form. Th

Seite 212

Contents Video ...1-12 iv HP ProL

Seite 213 - Configuration and Operation

Server Features Security Features The following sections outline the security features available for the ProLiant DL740 server. Software Security The

Seite 214 - Integrated Management Log

Server Features Hardware Security The ProLiant DL740 server has a switch on the I/O board that establishes the following hardware security features: •

Seite 215

Server Features Routine Maintenance For information about routine maintenance and safety precautions, refer to the server documentation CD included wi

Seite 216

Server Features 1-26 HP ProLiant DL740 Server User Guide HP CONFIDENTIAL Writer: Anna Roberts File Name: b-ch1 Server Features.doc Codename: Expedi

Seite 217

2 Installing the Server in a Rack This chapter specifies the procedures required to install a ProLiant DL740 server in an HP or industry-standard 19-

Seite 218 - Insight Manager 7

Installing the Server in a Rack Rack Installation Overview Installing the ProLiant DL740 server in a rack requires the following steps (detailed later

Seite 219 - Survey Utility

Installing the Server in a Rack Selecting a Site When installing the ProLiant DL740 server in a rack, the following standards must be met: • Space a

Seite 220

Installing the Server in a Rack CAUTION: Always use blanking panels to fill empty vertical spaces in the rack. This arrangement ensures proper airf

Seite 221

Installing the Server in a Rack Power Requirements WARNING: To reduce the risk of personal injury, fire, or damage to the equipment, do not overloa

Seite 222

Installing the Server in a Rack Power Supplies The following requirements apply to power supplies: • The ProLiant DL740 server has two hot-plug, redu

Seite 223

Contents Measuring with the Rack Template ... 2-13 HP ProLiant DL740 Server User

Seite 224 - Mouse Compliance Statement

Installing the Server in a Rack Grounding Requirements WARNING: To reduce the risk of electrical shock from high leakage currents, a reliable, grou

Seite 225 - European Union Notice

Installing the Server in a Rack Temperature Requirements To be sure of continued safe and reliable operation of the equipment, install the system in a

Seite 226 - BSMI Notice

Installing the Server in a Rack Shipping Box Contents Unpack the shipping boxes by following the instructions and illustrations printed on the outside

Seite 227 - Laser Safety Warnings

Installing the Server in a Rack Rack Considerations Consider the following issues when working with server rack systems. Rack Stability Rack stability

Seite 228 - Power Cords

Installing the Server in a Rack A single ProLiant DL740 server typically weighs between 48 and 61 kg (105 and 135 lbs), depending on configuration. If

Seite 229 - Battery Replacement Notice

Installing the Server in a Rack WARNING: To reduce the risk of personal injury or damage to the equipment, be sure that: • The leveling jacks are

Seite 230 - Electrostatic Discharge

Installing the Server in a Rack Preparing the Rack for Server Installation To prepare the rack for a server installation: • Measure with the rack tem

Seite 231 - Grounding Methods

Installing the Server in a Rack To identify the required space and location for the server with the template: 1. Identify the front side of the templ

Seite 232 - Server Error Messages

Installing the Server in a Rack 4. Using a pencil, mark the locations on the rack where you insert the rack rail tabs. 5. On the rack, mark the top

Seite 233 - LED Indicators and Switches

Installing the Server in a Rack Installing the Rack Rail Assemblies To install the rack rail assemblies in the rack: 1. From the front of the rack, i

Seite 234 - System Power LED Switch

Contents Hot-Replacing Memory...5-13 vi HP ProLiant DL740 Ser

Seite 235

Installing the Server in a Rack 3. Insert the two rail tabs from the end of the rack rail assembly into the marked holes on the inside of the rear of

Seite 236

Installing the Server in a Rack 5. Insert the two rail tabs from the rack rail assembly into the marked holes on the inside of the front of the rack.

Seite 237

Installing the Server in a Rack Attaching the Server Rails To attach the server rails to the ProLiant DL740 server chassis: IMPORTANT: Install the s

Seite 238

Installing the Server in a Rack Lightening the Chassis To make moving and lifting the server more manageable, HP recommends removing the server module

Seite 239

Installing the Server in a Rack Installing the Server in the Rack To complete the server rack installation, load the server onto the rack rails and re

Seite 240

Installing the Server in a Rack 3. Use two people to lift the server by its four lift handles (1) and carefully align the open ends of the server rai

Seite 241

Installing the Server in a Rack 5. Reach around the front of the server to press the rail-release levers at the front of both server rails, and conti

Seite 242

Installing the Server in a Rack 2-24 HP ProLiant DL740 Server User Guide HP CONFIDENTIAL Writer: Anna Roberts File Name: c-ch2 Installing the Serve

Seite 243 - Hot-Plug Fan LED Indicators

3 Server Access The ProLiant DL740 server provides easy access to all internal components for installation and maintenance. This chapter provides det

Seite 244

Server Access Server Access Overview The ProLiant DL740 server chassis facilitates the installation of hardware upgrades through the use of two remova

Seite 245

Contents Server Power... 7-7 HP ProLiant DL7

Seite 246

Server Access Unit Identification Switches (Front and Rear) The ProLiant DL740 server offers Unit Identification (UID) LED switches to aid in identify

Seite 247

Server Access Accessing the Host Module To access the host module to install or replace hot-plug fans or PCI Hot Plug boards: 1. Slide the chassis o

Seite 248 - Table D-3: DIMM status LEDs

Server Access Removing the Host Module Use the procedure in the preceding section, “Accessing the Host Module,” to install or replace hot-plug fans or

Seite 249

Server Access 5. Push the processor board lever latch down to release the lever (1). 6. Lift the processor board lever up (2) to release the board,

Seite 250 - Switches

Server Access 7. Push in on the sides of the module release levers (1) on the host module and rotate the top of the levers downward (2), as shown in

Seite 251

Server Access 11. To reassemble the server, slide the module into the chassis until the module release levers begin to rotate. Then push the levers s

Seite 252 - Troubleshooting Information

Server Access The system board is located in the bottom of the host module. Refer to Table 3-3 to identify components on the system board. Figure 3-6

Seite 253 - Server Startup Problems

Server Access Table 3-3: System Board Components Item Component 1 Fan 2 connector 2 Fan 1 connector 3 Memory cartridge 1 connector 4 Memory cart

Seite 254

Server Access Removing the Power and Media Module WARNING: The power and media module weighs more than 16 kg (35 lbs) HP recommends removing both p

Seite 255 - Table E-1: Diagnosis Steps

Server Access 4. Press the power supply latch to release the power supply handle (1). 5. Rotate the power supply handle outward (2) and slide the po

Seite 256

Contents Appendix A viii HP ProLiant DL740 Server User Guide HP CONFIDENTIAL Writer: Anna Roberts File Name: a-frnt.doc Codename: Expedition Part N

Seite 257

Server Access 6. Open the top access panels as shown in Figure 3-2 7. Slide the module release levers (1) on the power and media module, as shown in

Seite 258

Server Access 9. Press in on the module stop latches (1) and pull the module out of the chassis (2), as shown in Figure 3-9. Figure 3-9: Removing t

Seite 259

Server Access HP ProLiant DL740 Server User Guide 3-15 HP CONFIDENTIAL Writer: Anna Roberts File Name: d-ch3 Server Access.doc Codename: Expedition

Seite 260

4 Installing Hardware Options, Non-Hot-Plug The following instructions are provided as an overview for installing hardware option upgrades that requi

Seite 261

Installing Hardware Options, Non-Hot-Plug Intel Xeon Processor MP The ProLiant DL740 server supports either four or eight processors. • All processor

Seite 262

Installing Hardware Options, Non-Hot-Plug Figure 4-1: Processor board layout Item Description 1 Intel Xeon processor MP in socket 1 2 Intel Xeon p

Seite 263 - Problems After Initial Boot

Installing Hardware Options, Non-Hot-Plug Installing a Processor Board The ProLiant DL740 server is capable of supporting up to eight Intel Xeon proce

Seite 264

Installing Hardware Options, Non-Hot-Plug To install a processor board option kit (with four processors) into the host module: 1. Back up all data on

Seite 265

Installing Hardware Options, Non-Hot-Plug 7. Insert the processor board into processor board slot 2 of the module (1). 8. Push down the processor bo

Seite 266 - Redundant ROM Images

Installing Hardware Options, Non-Hot-Plug Non-Hot-Plug I/O Expansion The PCI-X slots of the ProLiant DL740 server I/O board support a variety of indus

Seite 267 - ° F 38.7° C

Contents PCI Hot Plug LED Indicators ... D-12 Memory Cartridge LED Indica

Seite 268 - System Battery

Installing Hardware Options, Non-Hot-Plug Table 4-1: I/O Expansion Slots Item Description Slots 1–2 PCI bus 7—Supports 64-bit PCI-X expansion board

Seite 269

Installing Hardware Options, Non-Hot-Plug To add an expansion board: 1. Press on the top (1) of the appropriate expansion slot release lever and open

Seite 270 - COMPAQ CONFIDENTIAL

Installing Hardware Options, Non-Hot-Plug 3. Insert the PCI/PCI-X expansion board into the appropriate expansion slot (1), pushing firmly until the b

Seite 271

Installing Hardware Options, Non-Hot-Plug HP has designed a self-latching slot-keeper feature to accommodate full-length expansion boards. Be sure tha

Seite 272

Installing Hardware Options, Non-Hot-Plug Installing the Integrated Array Bypass Use the Integrated Array Bypass kit to bypass the Smart Array 5i Cont

Seite 273

Installing Hardware Options, Non-Hot-Plug 6. Open the top left access panel, as shown in Chapter 3. 7. Slide the retaining clip (1) and remove the A

Seite 274

Installing Hardware Options, Non-Hot-Plug 8. Install the Integrated Array Bypass assembly, as shown in Figure 4-10. IMPORTANT: The Integrated Array

Seite 275

Installing Hardware Options, Non-Hot-Plug 9. Press on the top (1) of the appropriate expansion slot release lever and open the lever toward the rear

Seite 276

Installing Hardware Options, Non-Hot-Plug 11. Install the optional array controller board (1) as shown in Figure 4-12 and close the expansion slot re

Seite 277

Installing Hardware Options, Non-Hot-Plug HP ProLiant DL740 Server User Guide 4-17 HP CONFIDENTIAL Writer: Anna Roberts File Name: e-ch4 Install Ha