Switch Command Interface (SWCI)
ServerNet Nomadic Disk (Release 2) User’s Guide523968-001
6-39
Switch Protocol Error Messages
Recovery. Do the following:
1. Check the configuration of the switch module device and reconfigure if necessary.
2. Check the version of SWCI installed.
3. Power the switch module device off then back on again.
Cause. The slot number field in a response message received from the SCC did not
contain a valid slot number.
Effect. SWCI does not work properly.
Recovery. Do the following:
1. Check the configuration of the switch module device and reconfigure if necessary.
2. Check the version of SWCI installed.
3. Power the switch module device off then back on again.
Cause. The response type field in a response message received from the SCC did not
contain a valid value.
Effect. SWCI does not work properly.
Recovery. Do the following:
1. Check the configuration of the switch module device and reconfigure if necessary.
2. Check the version of SWCI installed.
3. Power the switch module device off then back on again.
Cause. The environment alert field in a response message received from the SCC did
not contain a valid value.
Effect. SWCI does not work properly.
***PROTOCOL ERROR*** SCC response message: invalid slot
number.
***PROTOCOL ERROR*** SCC response message: invalid response
type field.
***PROTOCOL ERROR*** SCC response message: invalid
environment alert field.