Hp OneView for VMware vCenter Bedienungsanleitung Seite 16

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 107
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 15
4. Select HP P2000 G3 MSA in the Type list, and then click Next.
The Add HP P2000 G3 MSA (2 of 4) page appears.
A P2000 G3 MSA System is managed by one or two controllers. After connecting to a
controller, the software discovers the other controllers, if applicable.
5. Enter the following connection parameters for one of the controllers managing the P2000 G3
MSA you want to add, and then click Next.
Controller host name or IP address
User name
Password
The Add HP P2000 G3 MSA (3 of 4) page appears, listing the selected storage array and
controllers.
6. Click Next.
The Add HP P2000 G3 MSA (4 of 4) page appears, listing the storage pools on the selected
P2000 G3 MSA System.
7. Select the Full Access check box for one or more storage pools to enable provisioning by the
Storage Module for vCenter.
If you will not perform provisioning operations on a particular storage pool, you do not need
to enable Full Access for that storage pool.
8. Click Finish.
The P2000 G3 MSA System is added to the Configured Arrays and Management Servers
list.
Adding HP P9000 arrays
To add an HP P9000 array:
1. Verify that a command device from the P9000 array is presented to the host running the
Storage Module for vCenter. Make sure that the security is disabled for the command device.
2. Log in to the Storage Administrator Portal.
For instructions, see About the Storage Administrator Portal” (page 10).
3. Click Add.
The Add Storage Array or Management Server (1 of ...) page appears.
4. Select HP P9000 Storage Array in the Type list, and then click Next.
The Add HP P9000 Storage Array (2 of 2) page appears. The available P9000 arrays are
listed by serial number.
5. Select an array.
6. Enter the Remote Web Console credentials, and then click Finish.
The array is added to the Configured Arrays and Management Servers list.
NOTE: The P9000 array does not support provisioning by the Storage Module for vCenter.
Adding HP XP arrays
To add an HP XP array:
1. Verify that a command device from the XP array is presented to the host running the Storage
Module for vCenter.
2. Log in to the Storage Administrator Portal.
For instructions, see About the Storage Administrator Portal” (page 10).
16 Configuring Insight Control for vCenter
Seitenansicht 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21 ... 106 107

Kommentare zu diesen Handbüchern

Keine Kommentare